Andersson, M., Johansson, L., Eckerman, K. & Mattsson, S. (2017). IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms. EJNMMI Research, 7, Article ID 88.
Öppna denna publikation i ny flik eller fönster >>IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms
2017 (Engelska)Ingår i: EJNMMI Research, ISSN 2191-219X, E-ISSN 2191-219X, Vol. 7, artikel-id 88Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer program, IDAC-Dose2.1, was developed based on the International Commission on Radiological Protection (ICRP)-specific absorbed fractions and computational framework of internal dose assessment given for reference adults in ICRP Publication 133. The program uses the radionuclide decay database of ICRP Publication 107 and considers 83 different source regions irradiating 47 target tissues, defining the effective dose as presented in ICRP Publications 60 and 103. The computer program was validated against another ICRP dosimetry program, Dose and Risk Calculation (DCAL), that employs the same computational framework in evaluation of occupational and environmental intakes of radionuclides. IDAC-Dose2.1 has a sub-module for absorbed dose calculations in spherical structures of different volumes and composition; this sub-module is intended for absorbed dose estimates in radiopharmaceutical therapy. For nine specific alpha emitters, the absorbed dose contribution from their decay products is also included in the committed absorbed dose calculations. Results: The absorbed doses and effective dose of I-131-iodide determined by IDAC-Dose2.1 were validated against the dosimetry program DCAL, showing identical results. IDAC-Dose2.1 was used to calculate absorbed doses for intravenously administered F-18-FDG and orally administered Tc-99m-pertechnetate and I-131-iodide, three frequently used radiopharmaceuticals. Using the tissue weighting factors from ICRP Publication 103, the effective dose per administered activity was estimated to be 0.016 mSv/MBq for F-18-FDG, 0.014 mSv/MBq for Tc-99m-pertechnetate, and 16 mSv/MBq for I-131-iodide. Conclusions: The internal dosimetry program IDAC-Dose2.1 was developed and applied to three radiopharmaceuticals for validation against DCAL and to generate improved absorbed dose estimations for diagnostic nuclear medicine using specific absorbed fraction values of the ICRP computational voxel phantoms. The sub-module for absorbed dose calculations in spherical structures 1 mm to 9 cm in diameter and different tissue composition was included to broaden the clinical usefulness of the program. The IDAC-Dose2.1 program is free software for research and available for download at http://www.idac-dose.org.

Ort, förlag, år, upplaga, sidor
Springer Berlin/Heidelberg, 2017
Nyckelord
Internal dosimetry, ICRP, IDAC, DCAL, Effective dose, Radiopharmaceuticals, Diagnostic nuclear dicine
Nationell ämneskategori
Radiologi och bildbehandling Arbetsmedicin och miljömedicin