Behrens, A., Eklund, A., Elgh, E., Smith, C., Williams, M. A. & Malm, J. (2014). A computerized neuropsychological test battery designed for idiopathic normal pressure hydrocephalus. Fluids and Barriers of the CNS, 11, Article ID 22.
Open this publication in new window or tab >>A computerized neuropsychological test battery designed for idiopathic normal pressure hydrocephalus
Show others...
2014 (English)In: Fluids and Barriers of the CNS, ISSN 2045-8118, E-ISSN 2045-8118, Vol. 11, article id 22Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: A tool for standardized and repeated neuropsychological assessments in patients with idiopathic normal pressure hydrocephalus (INPH) is needed. The objective of this study was to develop a computerized neuropsychological test battery designed for INPH and to evaluate its reliability, validity and patient's ability to complete the tests.

METHODS: Based on a structured review of the literature on neuropsychological testing in INPH, the eight tests most sensitive to the INPH cognitive profile were implemented in a computerized format. The Geriatric Depression Scale (GDS) was also included. Tests were presented on a touch-screen monitor, with animated instructions and speaker sound. The battery was evaluated with the following cohorts: A. Test-retest reliability, 44 healthy elderly; B. Validity against standard pen and pencil testing, 28 patients with various cognitive impairments; C. Ability to complete test battery, defined as completion of at least seven of the eight tests, 40 investigated for INPH.

RESULTS: A. All except the figure copy test showed good test-retest reliability, r = 0.67-0.90; B. A high correlation was seen between conventional and computerized tests (r = 0.66-0.85) except for delayed recognition and figure copy task; C. Seventy-eight percent completed the computerized battery; Patients diagnosed with INPH (n = 26) performed worse on all tests, including depression score, compared to healthy controls.

CONCLUSIONS: A new computerized neuropsychological test battery designed for patients with communicating hydrocephalus and INPH was introduced. Its reliability, validity for general cognitive impairment and completion rate for INPH was promising. After exclusion of the figure copy task, the battery is ready for clinical evaluation and as a next step we suggest validation for INPH and a comparison before and after shunt surgery.

TRIAL REGISTRATION: ClinicalTrials.org NCT01265251.

Keywords
Dementia, Hydrocephalus, Normal pressure, Neuropsychological tests, Neuropsychology, Reliability and validity, Software
National Category
Psychiatry Neurology
Research subject
Neurology
Identifiers
urn:nbn:se:umu:diva-96190 (URN)10.1186/2045-8118-11-22 (DOI)25279138 (PubMedID)
Available from: 2014-11-12 Created: 2014-11-12 Last updated: 2018-06-07Bibliographically approved
Behrens, A. (2014). Measurements in Idiopathic Normal Pressure Hydrocephalus: Computerized neuropsychological test battery and intracranial pulse waves. (Doctoral dissertation). Umeå: Umeå universitet
Open this publication in new window or tab >>Measurements in Idiopathic Normal Pressure Hydrocephalus: Computerized neuropsychological test battery and intracranial pulse waves
2014 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Idiopathic Normal Pressure Hydrocephalus (INPH) is a condition affecting gait, cognition and continence. Radiological examination reveals enlarged ventricles of the brain. A shunt that drains CSF from the ventricles to the abdomen often improves the symptoms. Much research on INPH has been focused on identifying tests that predict the outcome after shunt surgery. As part of this quest, there are attempts to find measurement methods of intracranial parameters that are valid, reliable, tolerable and safe for patients.

Today's technologies for intracranial pressure (ICP) measurement are invasive, often requiring a burr-hole in the skull. Recently, a method for non-invasive ICP measurements was suggested: the Pulsatile Index (PI) calculated from transcranial Doppler data assessed from the middle cerebral artery. In this thesis the relation between PI and ICP was explored in INPH patients during controlled ICP regulation by lumbar infusion. The confidence interval for predicted ICP, based on measured PI was too large for the method to be of clinical utility.

In the quest for better predictive tests for shunt success in INPH, recent studies have shown promising results with criteria based on cardiac related ICP wave amplitudes. The brain ventricular system, and the fluid surrounding the spinal cord are in contact. In this thesis it was shown that ICP waves could be measured via lumbar subarachnoid space, with a slight underestimation.

One of the cardinal symptoms of hydrocephalus is cognitive impairment. Neuropsychological studies have demonstrated cognitive tests that are impaired and improve after shunt surgery in INPH patients. However, there is currently no standardized test battery and different studies use different tests. In response, in this thesis a fully automated computerized neuropsychological test battery was developed. The validity, reliability, responsiveness to improvement after shunt surgery and feasibility for testing INPH patients was demonstrated. It was also demonstrated that INPH patients were impaired in all subtests, compared to healthy elderly. 

Place, publisher, year, edition, pages
Umeå: Umeå universitet, 2014. p. 67
Series
Umeå University medical dissertations, ISSN 0346-6612 ; 1689
Keywords
Hydrocephalus, Normal Pressure; Neuropsychological tests; Neuropsychology; Reliability and validity; Software; Dementia; intracranial pressure; spinal puncture; cerebrospinal fluid pressure; pulse pressure waves; Blood flow velocity; Middle cerebral artery; Pulsatility index
National Category
Medical and Health Sciences
Research subject
Neurology
Identifiers
urn:nbn:se:umu:diva-96195 (URN)978-91-7601-155-3 (ISBN)
Public defence
2014-12-05, Sal E04 Unod R1, Umeå, 13:00 (Swedish)
Opponent
Supervisors
Available from: 2014-11-14 Created: 2014-11-12 Last updated: 2018-06-07Bibliographically approved
Behrens, A., Lenfeldt, N., Qvarlander, S., Koskinen, L.-O., Malm, J. & Eklund, A. (2013). Are intracranial pressure wave amplitudes measurable through lumbar puncture?. Acta Neurologica Scandinavica, 127(4), 233-241
Open this publication in new window or tab >>Are intracranial pressure wave amplitudes measurable through lumbar puncture?
Show others...
2013 (English)In: Acta Neurologica Scandinavica, ISSN 0001-6314, E-ISSN 1600-0404, Vol. 127, no 4, p. 233-241Article in journal (Refereed) Published
Abstract [en]

 Objective The aim of this study was to investigate whether pulsations measured in the brain correspond to those measured in lumbar space, and subsequently whether lumbar punctures could replace invasive recordings. Methods In ten patients with normal pressure hydrocephalus, simultaneous recordings of the intracranial pressure (ICP; intraparenchymal) and lumbar pressure (LP; cerebrospinal fluid pressure) were performed. During registration, pressure was altered between resting pressure and 45mmHg using an infusion test. Data were analyzed regarding pulsations (i.e., amplitudes). Also, the pressure sensors were compared in a bench test. Results The correlation between intracranial and lumbar amplitudes was 0.98. At resting pressure, and moderately elevated ICP, intracranial pulse amplitudes exceeded that of lumbar space with about 0.9mmHg. At the highest ICP, the difference changed to 0.2mmHg. The bench test showed that the agreement of sensor readings was good at resting pressure, but reduced at higher amplitudes. Conclusions Compared to intracranial registrations, amplitudes measured through lumbar puncture were slightly attenuated. The bench test showed that differences were not attributable to dissimilarities of the sensor systems. A lumbar pressure amplitude measurement is an alternative to ICP recording, but the thresholds for what should be interpreted as elevated amplitudes need to be adjusted.

Keywords
intracranial pressure, spinal puncture, cerebrospinal fluid pressure, hydrocephalus, normal pressure, pulse pressure waves
National Category
Neurology
Identifiers
urn:nbn:se:umu:diva-68250 (URN)10.1111/j.1600-0404.2012.01701.x (DOI)000316215900004 ()
Available from: 2013-04-18 Created: 2013-04-15 Last updated: 2018-06-08Bibliographically approved
Behrens, A., Lenfeldt, N., Ambarki, K., Malm, J., Eklund, A. & Koskinen, L.-O. D. (2011). Intracranial Pressure and Pulsatility Index:  . Neurosurgery, 69(4), E1033-E1034
Open this publication in new window or tab >>Intracranial Pressure and Pulsatility Index:  
Show others...
2011 (English)In: Neurosurgery, ISSN 0148-396X, E-ISSN 1524-4040, Vol. 69, no 4, p. E1033-E1034Article in journal (Refereed) Published
Keywords
intracranial pressure, transcranial Doppler ultrasound
Identifiers
urn:nbn:se:umu:diva-45852 (URN)10.1227/NEU.0b013e31822999b7 (DOI)21694654 (PubMedID)
Available from: 2011-08-18 Created: 2011-08-18 Last updated: 2018-06-08Bibliographically approved
Behrens, A., Lenfeldt, N., Ambarki, K., Malm, J., Eklund, A. & Koskinen, L.-O. (2010). Transcranial Doppler pulsatility index: not an accurate method to assess intracranial pressure.. Neurosurgery, 66(6), 1050-1057
Open this publication in new window or tab >>Transcranial Doppler pulsatility index: not an accurate method to assess intracranial pressure.
Show others...
2010 (English)In: Neurosurgery, ISSN 0148-396X, E-ISSN 1524-4040, Vol. 66, no 6, p. 1050-1057Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: Transcranial Doppler sonography (TCD) assessment of intracranial blood flow velocity has been suggested to accurately determine intracranial pressure (ICP). OBJECTIVE: We attempted to validate this method in patients with communicating cerebrospinal fluid systems using predetermined pressure levels. METHODS: Ten patients underwent a lumbar infusion test, applying 4 to 5 preset ICP levels. On each level, the pulsatility index (PI) in the middle cerebral artery was determined by measuring the blood flow velocity using TCD. ICP was simultaneously measured with an intraparenchymal sensor. ICP and PI were compared using correlation analysis. For further understanding of the ICP-PI relationship, a mathematical model of the intracranial dynamics was simulated using a computer. RESULTS: The ICP-PI regression equation was based on data from 8 patients. For 2 patients, no audible Doppler signal was obtained. The equation was ICP = 23*PI + 14 (R = 0.22, P < .01, N = 35). The 95% confidence interval for a mean ICP of 20 mm Hg was -3.8 to 43.8 mm Hg. Individually, the regression coefficients varied from 42 to 90 and the offsets from -32 to +3. The mathematical simulations suggest that variations in vessel compliance, autoregulation, and arterial pressure have a serious effect on the ICP-PI relationship. CONCLUSIONS: The in vivo results show that PI is not a reliable predictor of ICP. Mathematical simulations indicate that this is caused by variations in physiological parameters.

Keywords
Blood flow velocity, hydrocephalus, intracranial pressure, middle cerebral artery, pulsatility indix
National Category
Medical and Health Sciences
Identifiers
urn:nbn:se:umu:diva-34863 (URN)10.1227/01.NEU.0000369519.35932.F2 (DOI)000278006200018 ()20495421 (PubMedID)
Available from: 2010-06-22 Created: 2010-06-22 Last updated: 2018-06-08Bibliographically approved
Organisations
Identifiers
ORCID iD: ORCID iD iconorcid.org/0000-0002-9099-0348

Search in DiVA

Show all publications