Adjeiwaah, M., Bylund, M., Lundman, J. A., Söderström, K., Zackrisson, B., Jonsson, J. H., . . . Nyholm, T. (2019). Dosimetric Impact of MRI Distortions: A Study on Head and Neck Cancers. International Journal of Radiation Oncology, Biology, Physics, 103(4), 994-1003
Open this publication in new window or tab >>Dosimetric Impact of MRI Distortions: A Study on Head and Neck Cancers
Show others...
2019 (English)In: International Journal of Radiation Oncology, Biology, Physics, ISSN 0360-3016, E-ISSN 1879-355X, Vol. 103, no 4, p. 994-1003Article in journal (Refereed) Published
Abstract [en]

Purpose: To evaluate the effect of magnetic resonance (MR) imaging (MRI) geometric distortions on head and neck radiation therapy treatment planning (RTP) for an MRI-only RTP. We also assessed the potential benefits of patient-specific shimming to reduce the magnitude of MR distortions for a 3-T scanner.

Methods and Materials: Using an in-house Matlab algorithm, shimming within entire imaging volumes and user-defined regions of interest were simulated. We deformed 21 patient computed tomography (CT) images with MR distortion fields (gradient nonlinearity and patient-induced susceptibility effects) to create distorted CT (dCT) images using bandwidths of 122 and 488 Hz/mm at 3 T. Field parameters from volumetric modulated arc therapy plans initially optimized on dCT data sets were transferred to CT data to compute a new plan. Both plans were compared to determine the impact of distortions on dose distributions.

Results: Shimming across entire patient volumes decreased the percentage of voxels with distortions of more than 2 mm from 15.4% to 2.0%. Using the user-defined region of interest (ROI) shimming strategy, (here the Planning target volume (PTV) was the chosen ROI volume) led to increased geometric for volumes outside the PTV, as such voxels within the spinal cord with geometric shifts above 2 mm increased from 11.5% to 32.3%. The worst phantom-measured residual system distortions after 3-dimensional gradient nonlinearity correction within a radial distance of 200 mm from the isocenter was 2.17 mm. For all patients, voxels with distortion shifts of more than 2 mm resulting from patient-induced susceptibility effects were 15.4% and 0.0% using bandwidths of 122 Hz/mm and 488 Hz/mm at 3 T. Dose differences between dCT and CT treatment plans in D-50 at the planning target volume were 0.4% +/- 0.6% and 0.3% +/- 0.5% at 122 and 488 Hz/mm, respectively.

Conclusions: The overall effect of MRI geometric distortions on data used for RTP was minimal. Shimming over entire imaging volumes decreased distortions, but user-defined subvolume shimming introduced significant errors in nearby organs and should probably be avoided.

Place, publisher, year, edition, pages
Elsevier, 2019
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
urn:nbn:se:umu:diva-157192 (URN)10.1016/j.ijrobp.2018.11.037 (DOI)000459153600031 ()30496879 (PubMedID)
Available from: 2019-04-15 Created: 2019-04-15 Last updated: 2019-04-15Bibliographically approved
Adjeiwaah, M., Bylund, M., Lundman, J. A., Thellenberg Karlsson, C., Jonsson, J. H. & Nyholm, T. (2018). Quantifying the effect of 3T MRI residual system and patient-induced susceptibility distortions on radiotherapy treatment planning for prostate cancer. International Journal of Radiation Oncology, Biology, Physics, 100(2), 317-324
Open this publication in new window or tab >>Quantifying the effect of 3T MRI residual system and patient-induced susceptibility distortions on radiotherapy treatment planning for prostate cancer
Show others...
2018 (English)In: International Journal of Radiation Oncology, Biology, Physics, ISSN 0360-3016, E-ISSN 1879-355X, Vol. 100, no 2, p. 317-324Article in journal (Refereed) Published
Abstract [en]

Purpose: To investigate the effect of magnetic resonance system- and patient-induced susceptibility distortions from a 3T scanner on dose distributions for prostate cancers.

Methods and Materials: Combined displacement fields from the residual system and patient-induced susceptibility distortions were used to distort 17 prostate patient CT images. VMAT dose plans were initially optimized on distorted CT images and the plan parameters transferred to the original patient CT images to calculate a new dose distribution.

Results: Maximum residual mean distortions of 3.19 mm at a radial distance of 25 cm and maximum mean patient-induced susceptibility shifts of 5.8 mm were found using the lowest bandwidth of 122 Hz per pixel. There was a dose difference of <0.5% between distorted and undistorted treatment plans. The 90% confidence intervals of the mean difference between the dCT and CT treatment plans were all within an equivalence interval of (−0.5, 0.5) for all investigated plan quality measures.

Conclusions: Patient-induced susceptibility distortions at high field strengths in closed bore magnetic resonance scanners are larger than residual system distortions after using vendor-supplied 3-dimensional correction for the delineated regions studied. However, errors in dose due to disturbed patient outline and shifts caused by patient-induced susceptibility effects are below 0.5%.

Place, publisher, year, edition, pages
Elsevier, 2018
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
urn:nbn:se:umu:diva-142319 (URN)10.1016/j.ijrobp.2017.10.021 (DOI)000423097500011 ()29229326 (PubMedID)
Available from: 2017-11-27 Created: 2017-11-27 Last updated: 2018-06-09Bibliographically approved
Adjeiwaah, M. (2017). Quality assurance for magnetic resonance imaging (MRI) in radiotherapy. (Licentiate dissertation). Umeå: Department of radiation sciences, Umeå university
Open this publication in new window or tab >>Quality assurance for magnetic resonance imaging (MRI) in radiotherapy
2017 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Magnetic resonance imaging (MRI) utilizes the magnetic properties of tissues to generate image-forming signals. MRI has exquisite soft-tissue contrast and since tumors are mainly soft-tissues, it offers improved delineation of the target volume and nearby organs at risk. The proposed Magnetic Resonance-only Radiotherapy (MR-only RT) work flow allows for the use of MRI as the sole imaging modality in the radiotherapy (RT) treatment planning of cancer. There are, however, issues with geometric distortions inherent with MR image acquisition processes. These distortions result from imperfections in the main magnetic field, nonlinear gradients, as well as field disturbances introduced by the imaged object. In this thesis, we quantified the effect of system related and patient-induced susceptibility geometric distortions on dose distributions for prostate as well as head and neck cancers. Methods to mitigate these distortions were also studied.

In Study I, mean worst system related residual distortions of 3.19, 2.52 and 2.08 mm at bandwidths (BW) of 122, 244 and 488 Hz/pixel up to a radial distance of 25 cm from a 3T PET/MR scanner was measured with a large field of view (FoV) phantom. Subsequently, we estimated maximum shifts of 5.8, 2.9 and 1.5 mm due to patient-induced susceptibility distortions. VMAT-optimized treatment plans initially performed on distorted CT (dCT) images and recalculated on real CT datasets resulted in a dose difference of less than 0.5%.

 The magnetic susceptibility differences at tissue-metallic,-air and -bone interfaces result in local B0 magnetic field inhomogeneities. The distortion shifts caused by these field inhomogeneities can be reduced by shimming.  Study II aimed to investigate the use of shimming to improve the homogeneity of local  B0 magnetic field which will be beneficial for radiotherapy applications. A shimming simulation based on spherical harmonics modeling was developed. The spinal cord, an organ at risk is surrounded by bone and in close proximity to the lungs may have high susceptibility differences. In this region, mean pixel shifts caused by local B0 field inhomogeneities were reduced from 3.47±1.22 mm to 1.35±0.44 mm and 0.99±0.30 mm using first and second order shimming respectively. This was for a bandwidth of 122 Hz/pixel and an in-plane voxel size of 1×1 mm2.  Also examined in Study II as in Study I was the dosimetric effect of geometric distortions on 21 Head and Neck cancer treatment plans. The dose difference in D50 at the PTV between distorted CT and real CT plans was less than 1.0%.

In conclusion, the effect of MR geometric distortions on dose plans was small. Generally, we found patient-induced susceptibility distortions were larger compared with residual system distortions at all delineated structures except the external contour. This information will be relevant when setting margins for treatment volumes and organs at risk.  

The current practice of characterizing MR geometric distortions utilizing spatial accuracy phantoms alone may not be enough for an MR-only radiotherapy workflow. Therefore, measures to mitigate patient-induced susceptibility effects in clinical practice such as patient-specific correction algorithms are needed to complement existing distortion reduction methods such as high acquisition bandwidth and shimming.

Place, publisher, year, edition, pages
Umeå: Department of radiation sciences, Umeå university, 2017. p. 54
Series
Umeå University medical dissertations, ISSN 0346-6612
Keywords
Magnetic resonance imaging, Radiotherapy, geometric distortions, patient-induced susceptibilities MR-only
National Category
Radiology, Nuclear Medicine and Medical Imaging Other Physics Topics Medical Image Processing
Research subject
radiofysik
Identifiers
urn:nbn:se:umu:diva-142603 (URN)978-91-7601-797-5 (ISBN)
Presentation
2017-12-20, Bergasalen, Byggnad 27, Umeå, 09:00 (English)
Opponent
Supervisors
Available from: 2017-12-11 Created: 2017-12-05 Last updated: 2018-06-09Bibliographically approved