umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Uncemented cups with and without screw holes in primary THA: a Swedish Hip Arthroplasty Register study with 22725 hips
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Orthopaedics.
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences.
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Orthopaedics.
Umeå University, Faculty of Medicine, Department of Surgical and Perioperative Sciences, Orthopaedics.
Show others and affiliations
(English)Manuscript (preprint) (Other academic)
Abstract [en]

Background and purpose: Uncemented cups in total hip arthroplasty (THA) are often augmented with additional screws to enhance their primary stability. We investigated whether there is a difference in the risk for revision between cups with screw holes and cups without screw holes.

Patients and methods: We analyzed the risk for cup revision of uncemented cups registered in the Swedish Hip Arthroplasty Register (SHAR) between 2000 and 2017 with respect to the presence of screw holes. Only patients with primary osteoarthritis (OA) were included. 22725 cups, including 12354 without screw holes and 10371 with screw holes, were evaluated. Revision rates at 2 and 10 years after the primary operation were analyzed.

Results: At a median follow-up time of 3.4 (0-18) years, 459 cup revisions were reported. The main reasons for cup revision during the whole observations time were infection, 52% of all cup revisions, and dislocation, 26% of all cup revisions. The survival rate with cup revision due to aseptic loosening as endpoint was 99.9% (95% CI 99.8-99.9) at 2 years for both cups with and cups without screw holes, and the survival rates at 10 years were 99.5% (CI 99.3-99.7) and 99.1% (CI 98.6-99.5), respectively. Cups without screw holes showed a decreased risk of revision due to any reason at both 2 years (adjusted hazard ratio [HR] 0.6, CI 0.5-0.8) and 10 years (HR 0.7, CI 0.5-0.9).

Interpretation: We found a very low revision rate for aseptic loosening with modern, uncemented cup designs. Cups with screw holes had an increased risk for revision due to any reason in patients with primary OA.

Keywords [en]
Total Hip Arthroplasty, uncemented, cup, revision, registry
National Category
Orthopaedics
Research subject
Orthopaedics
Identifiers
URN: urn:nbn:se:umu:diva-157458OAI: oai:DiVA.org:umu-157458DiVA, id: diva2:1297737
Available from: 2019-03-20 Created: 2019-03-20 Last updated: 2019-03-21
In thesis
1. The Uncemented Cup in Total Hip Arthroplasty: stability, Wear and Osteolysis
Open this publication in new window or tab >>The Uncemented Cup in Total Hip Arthroplasty: stability, Wear and Osteolysis
2019 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Background: Artificial hip joint replacement has undergone tremendous development in the past 100 years. In the beginning, complications, such as infection and early loosening, were the rule rather than the exception. Today, complications of any sort are rare during the first decade after the operation. Artificial hip joint replacement has been chosen as the "Operation of the Century" and has dramatically improved the quality of life of millions of patients. Unfortunately, in the long-term, prosthesis loosening due to pathological bone resorption (osteolysis) around the prosthesis is still common. Traditionally, the prosthesis is anchored in the bone with bone cement (Plexiglas). However, since this cementation method was suspected to cause late loosening, alternative methods, such as the implantation of so-called uncemented prostheses, have been developed and are being increasingly applied. Because the early movement of a prosthesis (migration) increases the risk of loosening, uncemented cups are often augmented with additional screws. The mechanisms regulating the early and late loosening of uncemented cups are not fully established. Wear particles from the artificial joint and intermittent fluid pressure on the bone appear to accelerate or even cause bone loss and can eventually lead to loosening of the prosthesis. Therefore, screw holes in the uncemented cup have been suspected to be a risk factor.

Aims: We have studied whether the additional augmentation of modern uncemented cups with screws, pegs or hydroxyapatite increases the long-term stability, affects the wear rate, influences the development of osteolysis, or has any impact on the risk of cup revision. Furthermore, we investigated whether computed tomography (CT), which is needed to detect osteolysis around the prosthesis, could also be used in the follow-up of migration studies without losing significant precision compared to radiostereometry (RSA), which is the gold standard for these measurements.

Patients and Methods: In studies I-III, we evaluated 48 hips (45 patients) randomized to receive cups with or without augmentation. As part of the 14-year follow-up with conventional radiographs of the pelvis, two pairs of stereo radiographs and a CT scan were obtained. Migration and wear were measured by RSA. The volume and type of osteolysis were determined on CT. Furthermore, we calculated the precision and limit of agreement of RSA and CT to compare these two modalities as tools for migration measurements.

In study IV, we compared the risk of cup revision between 10,371 uncemented cups with and 12,354 without screw holes, using data from the Swedish Hip Arthroplasty Register.

Results: Study I: Cup stability was equally good regardless of cup augmentation. The mean wear rate of the cup liner was high, at 0.21 mm/year, with no significant difference between the groups.

Study II: The limit of agreement between CT and RSA was 1.15°, 1.51°, and 0.70° for rotation and 0.46, 0.43, and 0.52 mm for translation. These results were within the described normal 99% confidence limits for precision in RSA: 0.3° to 2° for rotation and 0.15 to 0.6 mm for translation.

Study III: Osteolysis of some degree was visible in all 48 hips on CT. We found three different types of osteolytic lesions: type 1A, absent trabecular bone and a sclerotic border around the lesion; type 1B, absent trabecular bone and no sclerotic border; and type 2, reduced radiodensity and reduced trabecular number. Cups with screw holes were surrounded with larger osteolytic lesions, and osteolysis around these cups was more likely to be a type 1A lesion.

Study IV: Cups without screw holes showed a decreased risk of cup revision (implant exchange or removal) due to any reason at both 2 years (adjusted hazard ratio, HR: 0.6, confidence interval, CI: 0.5-0.8) and 10 years (HR: 0.7, CI: 0.5- 0.9). However, for aseptic loosening, there was no significant difference between cups with and without screw holes, with an implant survival rate of 99.9% (CI: 99.8-99.9) at 2 years and 99.1% (CI: 98.6-99.7) at 10 years.

Conclusion: Uncemented cups augmented with screws, pegs, or hydroxyapatite do not have improved long-term stability compared with cups with press-fit only. Unsealed screw holes in uncemented cups appear to be a risk factor for the development of larger osteolytic lesions. CT showed three different types of osteolytic lesions. The risk of aseptic loosening for modern uncemented cup designs is very low, and cups without additional augmentation do not have an increased revision rate. In contrast, the risk of cup revision for any reason was higher for cups with screw holes. CT can be used for migration studies for the longitudinal evaluation of patients with tantalum markers with precision comparable to that of RSA.

Place, publisher, year, edition, pages
Umeå: Umeå Universitet, 2019. p. 93
Series
Umeå University medical dissertations, ISSN 0346-6612 ; 2019
National Category
Orthopaedics
Identifiers
urn:nbn:se:umu:diva-157459 (URN)978-91-7855-038-8 (ISBN)
Public defence
2019-04-12, Sal B, trapphus A, 9 trappor, Norrlands universitetssjukhus, 13:00 (Swedish)
Opponent
Supervisors
Note

Felaktigt ISBN i kappan och spikbladet. Korrekt ISBN: 978-91-7855-038-8.

Available from: 2019-03-22 Created: 2019-03-20 Last updated: 2019-03-22Bibliographically approved

Open Access in DiVA

No full text in DiVA

Authority records BETA

Otten, Volker T CMukka, SebastianNilsson, Kjell GCrnalic, Sead

Search in DiVA

By author/editor
Otten, Volker T CMukka, SebastianNilsson, Kjell GCrnalic, Sead
By organisation
OrthopaedicsDepartment of Surgical and Perioperative Sciences
Orthopaedics

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 71 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf