Energianalys av MVG-gallerian, samt en jämförelse av beräkningsprogram
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2013 (Swedish)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesisAlternative title
Mapping of energy usage at the mall MVG, and a comparison between energy simulation softwares (English)
Abstract [sv]

På uppdrag av Sweco Systems i Umeå har detta examensarbete utförts under våren 2013. Syftet var att undersöka huruvida något av de energiberäknings-program som används på företaget kan anses vara lämpligt vid energikartläggningar av befintliga fastigheter.

Inledningsvis utfördes en energikartläggning av fastigheten Odin 12 i Umeå, som i huvudsak utgörs av gallerian MVG. Med resultaten från denna energikartläggning som grund beräknades därefter fastighetens energianvändning i två olika program – VIP-Energy och IDA Indoor Climate and Energy.

Resultaten från den inledande kartläggningen visar att fastigheten har ett lågt behov av fjärrvärme, vilket förklaras av fastighetens höga elförbrukning. Den stora användningen av el genererar stora mängder internvärme som, förutom att sänka fjärrvärmebehovet, även medför att fastigheten under hela året har ett kylbehov.

Utvärderingen av de två beräkningsprogrammen visar att VIP-Energy är ett lämpligt program att använda vid energikartläggningar. Programmet är enkelt och flexibelt, vilket medför att uppbyggandet av en beräkningsmodell går relativt snabbt. Vad gäller tidsåtgången för själva simuleringarna är också VIP-Energy det program som är klart snabbast.

Abstract [en]

This master thesis has been carried out in the spring of 2013, on behalf of Sweco Systems in Umeå. The aim of this work was to evaluate the possibilities of using any energy simulation software in the work of mapping energy usage of existing facilities. In this study two of the softwares that is being used in the company are evaluated – VIP-Energy and IDA Indoor Climate and Energy.

Initially a mapping of the energy usage was performed on the property Odin 12 in Umeå, which consists mainly of the mall MVG. The energy usage was then simulated with the two different softwares.

The mapping of energy usage shows that the building has a low annually need of space heating. This is due to the fact that the consumption of electricity in the building is very high, which leads to very high internal loads and a low need for additional heating. For the same reason, a need of space cooling is present during the whole year.

The evaluation of the two energy simulation softwares shows that VIP-Energy is a suitable program for energy mapping. The program is both simple and flexible which reduces the time needed for creating the model.  Considering the time for the actual calculations, VIP-Energy is the program that is by far the fastest.

Place, publisher, year, edition, pages
2013. , p. 49
Keywords [sv]
energikartläggning, energiberäkningsprogram, VIP-Energy, IDA
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:umu:diva-71555OAI: oai:DiVA.org:umu-71555DiVA, id: diva2:624849
Educational program
Master of Science Programme in Energy Engineering
Supervisors
Examiners
Available from: 2013-06-11 Created: 2013-06-03 Last updated: 2013-06-11Bibliographically approved

Open Access in DiVA

fulltext(4458 kB)1246 downloads
File information
File name FULLTEXT01.pdfFile size 4458 kBChecksum SHA-512
c7bf11552d44e9664a45149efa1933c08661ff784da2c664bd9cda385ec44e185dfcf9e2b4272f0bc7e4e18afba0af014f9f6d77f20eb2ac17426468a96b9dfb
Type fulltextMimetype application/pdf

By organisation
Department of Applied Physics and Electronics
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 1246 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1482 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf