umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0001-7431-8335
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
2019 (engelsk)Inngår i: Sensors, ISSN 1424-8220, E-ISSN 1424-8220, Vol. 19, nr 5, artikkel-id 1241Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Ordinal scales with low resolution are used to assess arm function in clinic. These scales may be improved by adding objective kinematic measures. The aim was to analyze within-subject, inter-rater and overall reliability (i.e., including within-subject and inter-rater reliability) and check the system's validity of kinematic measures from inertial sensors for two such protocols on one person. Twenty healthy volunteers repeatedly performed two tasks, finger-to-nose and drinking, during two test sessions with two different raters. Five inertial sensors, on the forearms, upper arms and xiphoid process were used. Comparisons against an optical camera system evaluated the measurement validity. Cycle time, range of motion (ROM) in shoulder and elbow were calculated. Bland-Altman plots and linear mixed models including the generalizability (G) coefficient evaluated the reliability of the measures. Within-subject reliability was good to excellent in both tests (G = 0.80-0.97) and may serve as a baseline when assessing upper extremities in future patient groups. Overall reliability was acceptable to excellent (G = 0.77-0.94) for all parameters except elbow axial rotation in finger-to-nose task and both elbow axial rotation and flexion/extension in drinking task, mainly due to poor inter-rater reliability in these parameters. The low to good reliability for elbow ROM probably relates to high within-subject variability. The sensors provided good to excellent measures of cycle time and shoulder ROM in non-disabled individuals and thus have the potential to improve today's assessment of arm function.

sted, utgiver, år, opplag, sider
MDPI, 2019. Vol. 19, nr 5, artikkel-id 1241
Emneord [en]
inter-rater reliability, inertial sensor, kinematics, upper limb, arm function
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-158105DOI: 10.3390/s19051241ISI: 000462540400260PubMedID: 30870999OAI: oai:DiVA.org:umu-158105DiVA, id: diva2:1304597
Tilgjengelig fra: 2019-04-12 Laget: 2019-04-12 Sist oppdatert: 2019-04-12bibliografisk kontrollert

Open Access i DiVA

fulltext(5517 kB)80 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 5517 kBChecksum SHA-512
f2320f4d2919fb0a75742b087cacc5e091858df9bb450ea7ab2d23abf2905a99fc5356813c4325d27f5442e1f83ff5cc78f7b3f309987823d017ea63da262b7a
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Öhberg, FredrikBäcklund, TomasSundström, NinaGrip, Helena

Søk i DiVA

Av forfatter/redaktør
Öhberg, FredrikBäcklund, TomasSundström, NinaGrip, Helena
Av organisasjonen
I samme tidsskrift
Sensors

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 80 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 267 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf