Distortion Product Otoacoustic Emissions and Intracranial Pressure During CSF Infusion Testing
Umeå universitet, Medicinska fakulteten, Institutionen för farmakologi och klinisk neurovetenskap, Klinisk neurovetenskap.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Vise andre og tillknytning
2016 (engelsk)Inngår i: Aerospace medicine and human performance, ISSN 2375-6314, Vol. 87, nr 10, s. 844-851Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: A noninvasive method to monitor changes in intracranial pressure (ICP) is required for astronauts on long-duration spaceflight who are at risk of developing the Visual Impairment/Intracranial Pressure syndrome that has some, but not all of the features of idiopathic intracranial hypertension. We assessed the validity of distortion product otoacoustic emissions (DPOAEs) to detect changes in ICP. METHODS: Subjects were eight patients undergoing medically necessary diagnostic cerebrospinal fluid (CSF) infusion testing for hydrocephalus. DPOAE measurements were obtained with an FDA-approved system at baseline and six controlled ICP levels in similar to 3 mmHg increments in random order, with a range from 10.8 +/- 2.9 mmHg (SD) at baseline to 32.3 +/- 4.1 mmHg (SD) at level 6. RESULTS: For f2 frequencies between 800 and 1700 Hz, when ICP was >= 12 mmHg above baseline ICP, DPOAE angles increased significantly and DPOAE magnitudes decreased significantly, but less robustly. DISCUSSION: Significant changes in DPOAE angle and magnitude are seen when ICP is >= 12 mmHg above a subject's supine baseline ICP during CSF infusion testing. These results suggest that the changes in DPOAE angle and magnitude seen with change in ICP are physiologically based, and suggest that it should be possible to detect pathological ICP elevation using DPOAE measurements. To use DPOAE for noninvasive estimation of ICP during spaceflight will require baseline measurements in the head-up, supine, and head-down positions to obtain baseline DPOAE values at different ICP ranges.

sted, utgiver, år, opplag, sider
2016. Vol. 87, nr 10, s. 844-851
Emneord [en]
intracranial pressure, noninvasive measures, otoacoustic emissions, hydrocephalus, idiopathic intracranial hypertension, visual impairment intracranial pressure, spaceflight
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-126729DOI: 10.3357/AMHP.4572.2016ISI: 000384034500002OAI: oai:DiVA.org:umu-126729DiVA, id: diva2:1039211
Tilgjengelig fra: 2016-10-21 Laget: 2016-10-13 Sist oppdatert: 2018-06-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Malm, JanEklund, Anders

Søk i DiVA

Av forfatter/redaktør
Malm, JanEklund, Anders
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 142 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf