Comparative analysis of optimal operation strategies for district heating and cooling system based on design and actual load
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
Vise andre og tillknytning
2017 (engelsk)Inngår i: Applied Energy, ISSN 0306-2619, E-ISSN 1872-9118, Vol. 205, s. 577-588Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Computational load significantly influences energy and cost savings when developing an operation strategy for a district heating and cooling system. In this study, a model was identified to study the effects of the difference between design load and actual load on an optimal operation strategy. The established model is strongly dependent on the economy principle, and the proposed optimal strategy could achieve a dynamic balance between the users' load and the system energy supply. This model was validated at 30% load rate, which demonstrated an obvious cost saving of 63.6% under the actual load and 42.2% under the design load. Based on the current strategy, the optimal strategy at different load rates was analyzed with respect to two characteristics of each subsystem: energy outputs and operation costs. Furthermore, in the optimal strategy, changes in total operation costs and cost savings rates under different load rates are also discussed. The results showed that, when the load rate was changed from 30 to 75%, the savings rates based on the design load were 42.2, 17.9, 2.5, and 12.6%, and the savings rates based on the actual load were 63.6, 49.8, 34.3, and 25.7%, respectively. Based on the actual load, the energy savings advantage of the optimal operation strategy could be maximized, in particular, during the initial stage of project construction. Furthermore, the commercial software MATLAB was used for programming and calculations. The simulation results indicated that the application of the combined cooling, heating, and power system could significantly improve the cost-effectiveness.

sted, utgiver, år, opplag, sider
2017. Vol. 205, s. 577-588
Emneord [en]
District heating and cooling, Design load, Actual load, Optimal operation strategy
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-142250DOI: 10.1016/j.apenergy.2017.07.104ISI: 000414817100043OAI: oai:DiVA.org:umu-142250DiVA, id: diva2:1164229
Tilgjengelig fra: 2017-12-11 Laget: 2017-12-11 Sist oppdatert: 2018-06-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Yang, Bin

Søk i DiVA

Av forfatter/redaktør
Yang, Bin
Av organisasjonen
I samme tidsskrift
Applied Energy

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 127 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf