umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Sol-air thermometer measurement of heat transfer coefficient at building outdoor surface
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
2018 (engelsk)Inngår i: Cold Climate HVAC 2018: Sustainable Buildings in Cold Climates, Springer, 2018, s. 329-338Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

There exists a building energy performance gap between theoretical simulations and the actual energy usage as measured. One potential reason for this gap might be a mismatch between predicted and measured values of the heat flux q through the building envelope. There is therefore a need to develop accurate and more cost-efficient methods for measurement of q. The standard ISO 9869-1 states that, at the outdoor surface, q = ho(Ts − Tenv), where ho is the overall heat transfer coefficient, including both convective and radiative components, Tenv is the environmental temperature, and Ts is the temperature of the building surface. It has previously been shown that the sol-air thermometer (SAT) could be used for convenient measurement of Tenv under dark conditions. In the present work, two SAT units, one heated and the other unheated, were employed for accurate outdoor measurements of ho in cold winter climate. Validation was performed by comparison of results from the new method against measurements, where previously established methodology was used. With current operating conditions, the measurement uncertainty was estimated to be 3.0 and 4.4%, for ho equal to 13 and 29 Wm−2K−1, respectively. The new SAT steady-state method is more cost-effective compared to previous methodology, in that the former involves fewer input quantities (surface emissivity and infrared radiation temperature are unnecessary) to be measured, while giving the same ho results, without any sacrifice in accuracy. SAT methodology thus enables measurement of both Tenv and ho, which characterizes the building thermal environment, and supports estimation of q.

sted, utgiver, år, opplag, sider
Springer, 2018. s. 329-338
Serie
Springer Proceedings in Energy
Emneord [en]
Heat transfer coefficient, Sol-air thermometer, Environmental temperature, Building energy performance gap
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-152725DOI: 10.1007/978-3-030-00662-4_28OAI: oai:DiVA.org:umu-152725DiVA, id: diva2:1257460
Konferanse
CONFERENCE on 9th International Cold Climate HVAC 2018, Kiruna, Sweden, March 12-15, 2018
Tilgjengelig fra: 2018-10-21 Laget: 2018-10-21 Sist oppdatert: 2019-06-19bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Ohlsson, K.E. AndersÖstin, RonnyOlofsson, Thomas

Søk i DiVA

Av forfatter/redaktør
Ohlsson, K.E. AndersÖstin, RonnyOlofsson, Thomas
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 85 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf