Sol-air thermometer measurement of heat transfer coefficient at building outdoor surface
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
2018 (engelsk)Inngår i: Energy Procedia, ISSN 1876-6102, E-ISSN 1876-6102, Vol. 132, s. 357-362Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Heat flow measurement with a heat flow meter is a standardized method (ISO 9869-1) to estimate thermal transmittance (U-value) of a building element. The heat flow meter is a thin plate mounted on top of the surface of the element, and measures the heat flux q through the plate. The measured q is the product of the difference in temperatures between exterior and interior environment, and the U-value. The heat transferred from the element is based on the radiant and the convective heat transfer.

ISO 9869-1 specifies that the environment temperature Te “is a notional temperature" and it "cannot be measured directly” (section A.3.1). The air temperature Ta is proposed as a reasonable approximation for the indoor environment, while overcast conditions and absence of significant solar radiation are specified conditions for replacing Te with Ta for the exterior environment.

The sol-air thermometer (SAT) measures the sol-air temperature Tsa, i.e. the equivalent temperature of the convective and the radiative environment. In the absence of solar radiation, Te = Tsa. SAT is a sensor consisting of a thin flat solid plate, of high thermal conductivity. The front side of the sensor is exposed to the environment, whose Tsa is to be measured, and the backside is thermally insulated. The temperature of the SAT-plate equals Tsa.

In this work we propose introduction of the measured Te in the existing standard (ISO 9869-1). The method for measurement of Tsa, using the SAT, has been demonstrated experimentally for different periods, without solar radiation present and under stable climatic conditions.

sted, utgiver, år, opplag, sider
Elsevier, 2018. Vol. 132, s. 357-362
Emneord [en]
Environmental temperature, Sol-air thermometer, Heat transfer coefficient, Thermal transmittance
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-152736DOI: 10.1016/j.egypro.2017.09.632OAI: oai:DiVA.org:umu-152736DiVA, id: diva2:1257470
Forskningsfinansiär
Swedish Energy AgencyThe Kempe FoundationsTilgjengelig fra: 2018-10-21 Laget: 2018-10-21 Sist oppdatert: 2018-11-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Ohlsson, K.E. AndersÖstin, RonnyOlofsson, Thomas

Søk i DiVA

Av forfatter/redaktør
Ohlsson, K.E. AndersÖstin, RonnyOlofsson, Thomas
Av organisasjonen
I samme tidsskrift
Energy Procedia

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 72 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf