Zero TE-based pseudo-CT image conversion in the head and its application in PET/MR attenuation correction and MR-guided radiation therapy planning
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
Vise andre og tillknytning
2018 (engelsk)Inngår i: Magnetic Resonance in Medicine, ISSN 0740-3194, E-ISSN 1522-2594, Vol. 80, nr 4, s. 1440-1451Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Purpose: To describe a method for converting Zero TE (ZTE) MR images into Xray attenuation information in the form of pseudo-CT images and demonstrate its performance for (1) attenuation correction (AC) in PET/MR and (2) dose planning in MR-guided radiation therapy planning (RTP).

Methods: Proton density-weighted ZTE images were acquired as input for MRbased pseudo-CT conversion, providing (1) efficient capture of short-lived bone signals, (2) flat soft-tissue contrast, and (3) fast and robust 3D MR imaging. After bias correction and normalization, the images were segmented into bone, soft-tissue, and air by means of thresholding and morphological refinements. Fixed Hounsfield replacement values were assigned for air (-1000 HU) and soft-tissue (142 HU), whereas continuous linear mapping was used for bone.

Results: The obtained ZTE-derived pseudo-CT images accurately resembled the true CT images (i. e., Dice coefficient for bone overlap of 0.73 +/- 0.08 and mean absolute error of 123 +/- 25 HU evaluated over the whole head, including errors from residual registration mismatches in the neck and mouth regions). The linear bone mapping accounted for bone density variations. Averaged across five patients, ZTE-based AC demonstrated a PET error of -0.04 +/- 1.68% relative to CT-based AC. Similarly, for RTP assessed in eight patients, the absolute dose difference over the target volume was found to be 0.23 +/- 0.42%.

Conclusion: The described method enables MR to pseudo-CT image conversion for the head in an accurate, robust, and fast manner without relying on anatomical prior knowledge. Potential applications include PET/MR-AC, and MR-guided RTP.

sted, utgiver, år, opplag, sider
Wiley-Blackwell, 2018. Vol. 80, nr 4, s. 1440-1451
Emneord [en]
attenuation correction, PET/MR, pseudo-CT, radiation therapy planning, RTP, RUFIS, synthetic CT, ZTE
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-153707DOI: 10.1002/mrm.27134ISI: 000448869800015PubMedID: 29457287OAI: oai:DiVA.org:umu-153707DiVA, id: diva2:1268186
Tilgjengelig fra: 2018-12-05 Laget: 2018-12-05 Sist oppdatert: 2018-12-05bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Bylund, MikaelJonsson, JoakimLundman, JosefNyholm, Tufve

Søk i DiVA

Av forfatter/redaktør
Bylund, MikaelJonsson, JoakimLundman, JosefNyholm, Tufve
Av organisasjonen
I samme tidsskrift
Magnetic Resonance in Medicine

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 83 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf