Stabilisation splints produced by artificial intelligence: A pilot study
Umeå universitet, Medicinska fakulteten, Institutionen för odontologi.
Umeå universitet, Medicinska fakulteten, Institutionen för odontologi.
2024 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
Abstract [en]

Background: Annually approximately 50 000 stabilisation splints (SS) are produced in Sweden. Variations in fit of the splints affects the adjustment time needed and may also affect the quality of the treatment. Artificial Intelligence (AI) has been introduced to produce SS. The AI technique may offer more standardized splints.

Aims: 1. To evaluate the fit and contact pattern of AI-manufactured SS.  2. To test a trigonometric calculation model of the intermaxillary angle (α) and whether that angle affects the contact pattern of the lower jaw teeth against the SS. 3. To assess the inter- and intra-individual reliability of repeated α measurement. 

Methods: The study was divided into two parts. First, evaluation forms were collected from the Umeå University dentistry program to assess the fit, contact pattern and adjustment time of AI- produced SS. Secondly, a clinical- and laboratory exploratory study; Five participants were scanned for SS, and the SS was evaluated upon delivery. A calculation model was developed and multiple α measurements of digital representations of the upper and lower jaw in a 3D program assessed intra- and interindividual reliability.

Results: The fit, retention and design of the SS’s were generally without remark. Initial contact patterns showed wide variation and only a few SS had optimal initial contact patterns. No significant correlation between α and contact pattern was found. The intra- and interindividual measurements showed excellent reliability.

Conclusion: There exists a wide variation in initial contact patterns on AI-produced SS. It is possible to calculate α with high reproducibility.

sted, utgiver, år, opplag, sider
2024. , s. 21
Emneord [en]
Stabilisation splint, artificial intelligence, contact pattern
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-233025OAI: oai:DiVA.org:umu-233025DiVA, id: diva2:1921989
Eksternt samarbeid
Bra Tänder Sweden AB
Utdanningsprogram
Dentistry Programme
Veileder
Examiner
Tilgjengelig fra: 2024-12-17 Laget: 2024-12-17 Sist oppdatert: 2024-12-17bibliografisk kontrollert

Open Access i DiVA

fulltext(684 kB)59 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 684 kBChecksum SHA-512
7bf369d7cc6ab5805ce4aa64a1268bf244cf88c310c4cc4ce0498b6169382b0c53801eff8a2b8e5b9e0eb8f3019af948817f38a20fdc5cda831f024ac3f1c183
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 59 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 311 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf