umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Impact on visual function from light scattering and glistenings in intraocular lenses, a long-term study
Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.
Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.
2011 (engelsk)Inngår i: Acta Ophthalmologica, ISSN 1755-375X, E-ISSN 1755-3768, Vol. 89, nr 8, s. 724-728Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Purpose: To investigate the impact on visual function from light scattering and glistenings in intraocular lenses (IOLs) in patients who had cataract surgery 10 years previously. Setting: Eye clinic, Norrlands university hospital, Umeå, Sweden.

Methods: One hundred and three patients, who had phacoemulsification with implantation of Acrysof((R)) MA60BM IOLs 10 years previously, were evaluated with best corrected visual acuity (VA), and low contrast visual acuity (LCVA) 10% and 2.5%. The light scattering from the IOLs was measured by Scheimpflug photography. The degree of glistenings was also quantified at the slit-lamp. Eyes with coexisting pathology that could affect VA and LCVA were excluded.

Results: The patients were divided into various groups according to the degree of light scattering and grade of glistenings. In two subsets of patients, paired data from the patients' eyes were analysed. It was not possible to detect any significant impact on visual function, best corrected visual acuity (BCVA) and LCVA 10% and 2.5% in eyes with a more pronounced light scattering or a higher grade of glistenings seen at the slit-lamp. The correlation between IOL dioptric power and both the total light scattering of the IOL, and the subjective grading of the intensity of the glistenings at the slit-lamp was statistically significant (r(P) = 0.25; p = 0.012; r(S) = 0.23; p = 0.019, respectively).

Conclusion: Most patients in this case series operated 10 years previously had severe glistenings and a high level of light scattering from their intraocular lenses. No detectable impact on BCVA, LCVA 10% and 2.5% was found.

sted, utgiver, år, opplag, sider
2011. Vol. 89, nr 8, s. 724-728
Emneord [en]
glistenings;intraocular lens;light scattering;long-term;visual function
HSV kategori
Forskningsprogram
oftalmiatrik
Identifikatorer
URN: urn:nbn:se:umu:diva-34172DOI: 10.1111/j.1755-3768.2009.01833.xPubMedID: 20064111Lokal ID: 744OAI: oai:DiVA.org:umu-34172DiVA, id: diva2:319574
Tilgjengelig fra: 2010-05-18 Laget: 2010-05-18 Sist oppdatert: 2018-06-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Mönestam, EvaBehndig, Anders

Søk i DiVA

Av forfatter/redaktør
Mönestam, EvaBehndig, Anders
Av organisasjonen
I samme tidsskrift
Acta Ophthalmologica

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 176 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf