Electron contamination in clinical high energy photon beams
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
1996 (engelsk)Inngår i: Medical physics (Lancaster), ISSN 0094-2405, Vol. 23, nr 11, s. 1873-1881Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The electron contamination in photon beams has been investigated by means of contaminating lepton depth doses and dose profiles in different geometries with two 20 MV beams. Different components of this contamination have been investigated separately by systematically adding contamination to a ''clean'' reference field. At 20 MV, the air generated electrons were found to be almost negligible compared to the electrons originating from the accelerator head when measurements were performed in standard fields at SSDs between 80 and 120 cm. The total electron part of the depth dose curve was then almost the same, i.e., independent of SSD, when the collimator opening was held fixed. However, when different accessories such as a shaping block and different attenuating plates were located in the beam path below the collimators, a large SSD dependence of the electron contamination was noticed. A comparison was also made between two machines, one equipped with a multileaf collimator, with similar beam qualities at 20 MV. These measurements indicate that the interior view of the treatment head seen by the detector (mainly the flattening filter, monitor chamber, or other electron generating material) influences the magnitude of the electron contamination. When the collimator opening is decreased the electron contamination will also decrease as parts of the electron source will be shielded by the collimator blocks.

sted, utgiver, år, opplag, sider
1996. Vol. 23, nr 11, s. 1873-1881
Emneord [en]
radiotherapy, x−ray dosimetry, photon beams, electrons, radiation dose distributions, depth profiles, leptons, collimators, neoplasms, secondary beams
Identifikatorer
URN: urn:nbn:se:umu:diva-39956DOI: 10.1118/1.597750ISI: A1996VU69100007OAI: oai:DiVA.org:umu-39956DiVA, id: diva2:396920
Tilgjengelig fra: 2011-02-11 Laget: 2011-02-11 Sist oppdatert: 2018-06-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Sjögren, RickardKarlsson, Mikael

Søk i DiVA

Av forfatter/redaktør
Sjögren, RickardKarlsson, Mikael
Av organisasjonen
I samme tidsskrift
Medical physics (Lancaster)

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 249 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf