Theoretical and experimental determination of phantom scatter factors for photon fields with different radial energy variation
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
1996 (engelsk)Inngår i: Physics in Medicine and Biology, ISSN 0031-9155, E-ISSN 1361-6560, Vol. 41, nr 12, s. 2687-2694Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The output factor used for monitor unit determination in radiotherapy can be divided into two factors: the head scatter factor and the phantom scatter factor. Theoretical and experimental phantom scatter factors have been compared for different beam qualities between 4 MV and 50 MV and field sizes from 5 cm x 5 cm to 30 cm x 30 cm. The theoretical data were obtained through a convolution method based on Monte Carlo calculated energy spectra and dose kernels. The calculations have been performed both for accelerators with a rather large energy variation within the field and for accelerators with a constant energy distribution in the field. Deviations between theoretical and experimental data were found to be less than 1%.

sted, utgiver, år, opplag, sider
1996. Vol. 41, nr 12, s. 2687-2694
Identifikatorer
URN: urn:nbn:se:umu:diva-39955DOI: 10.1088/0031-9155/41/12/008ISI: A1996VY19100008OAI: oai:DiVA.org:umu-39955DiVA, id: diva2:396921
Tilgjengelig fra: 2011-02-11 Laget: 2011-02-11 Sist oppdatert: 2018-06-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Karlsson, Mikael

Søk i DiVA

Av forfatter/redaktør
Karlsson, Mikael
Av organisasjonen
I samme tidsskrift
Physics in Medicine and Biology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 39 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf