umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Aortic valve replacement normalizes left ventricular twist function
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Medicin.
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Kardiologi.
Umeå universitet, Medicinska fakulteten, Institutionen för folkhälsa och klinisk medicin, Kardiologi.
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap.
Vise andre og tillknytning
2011 (engelsk)Inngår i: Interactive Cardiovascular and Thoracic Surgery, ISSN 1569-9293, E-ISSN 1569-9285, Vol. 12, nr 5, s. 701-706Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The aim of this study was to assess the effect of aortic valve replacement (AVR) on left ventricular (LV) twist function. We studied 28 severe aortic stenosis (AS) patients with normal LV ejection fraction (EF) before and six months after AVR. LV long axis function was assessed using M-mode and tissue Doppler and twist function using speckle tracking echocardiography. The data were compared with 28 age and sex-matched normal controls. In patients, LVEF remained unchanged after AVR. LV long axis function was reduced before surgery but normalized after AVR. LV twist was increased before (19.7 ± 5.7° vs. 12.9 ± 3.2°, P<0.001) and normalized after AVR (14.4 ± 5.2 °, P < 0.001). In normals, LV twist correlated with LV fractional shortening (r = 0.81, P<0.001) but not with EF. This relationship was reversed in patients before ( r= 0.52, P < 0.01) and after AVR (r = 0.34, P = ns). In patients with severe AS and normal EF, LV twist is exaggerated suggesting potential compensation for the reduced long axis function. These disturbances normalize within six months of AVR but lose their relationship with basal LV function.

sted, utgiver, år, opplag, sider
2011. Vol. 12, nr 5, s. 701-706
Emneord [en]
Aortic stenosis; Aortic valve replacement; Left ventricular function; Twist
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-45905DOI: 10.1510/icvts.2010.262303PubMedID: 21303867OAI: oai:DiVA.org:umu-45905DiVA, id: diva2:435702
Tilgjengelig fra: 2011-08-19 Laget: 2011-08-19 Sist oppdatert: 2018-06-08bibliografisk kontrollert
Inngår i avhandling
1. Effect of valve replacement for aortic stenosis on ventricular function
Åpne denne publikasjonen i ny fane eller vindu >>Effect of valve replacement for aortic stenosis on ventricular function
2011 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

BackgroundAortic stenosis (AS) is the commonest valve disease in the West. Aortic valve replacement (AVR) remains the only available management for AS and results in improved symptoms and recovery of ventricular functions. In addition, it is well known that AVR results in disruption of LV function mainly in the form of reversal of septal motion as well as depression of right ventricular (RV) systolic function. The aim of this thesis was to study, in detail, the early and mid-term response of ventricular function to AVR procedures (surgical and TAVI) as well as post operative patients’ exercise capacity.

MethodsWe studied LV and RV function by Doppler echocardiography and speckle tracking echocardiography (STE) in the following 4 groups; (1) 30 severe AS patients (age 62±11 years, 19 male) with normal LV ejection fraction (EF) who underwent AVR, (2) 20 severe AS patients (age 79±6 years, 14 male) who underwent TAVI, (3) 30 healthy controls (age 63±11 years, 16 male), (4) 21 healthy controls (age 57±9 years, 14 male) who underwent exercise echocardiography.

Results: After one week of TAVI, the septal radial motion and RV tricuspid annulus peak systolic excursion (TAPSE) were not different from before, while surgical AVR had significantly reversed septal radial motion and TAPSE dropped by 70% compared to before. The extent of the reversed septal motion correlated with that of TAPSE (r=0.78, p<0.001) in the patients as a whole after AVR and TAVI (Study I). Compared with controls, the LV twist function was increased in AS patients before and normalized after 6 months of surgical AVR. In controls, the LV twist correlated with LV fractional shortening (r=0.81, p<0.001), a relationship which became weak in patients before (r=0.52, p<0.01) and after AVR (r=0.34, p=ns) (Study II). After 6 months of surgical AVR, the reversed septal radial motion was still significantly lower than before. The septal peak displacement also decreased and its time became prolonged. In contrast, the LV lateral wall peak displacement increased and the time to peak displacement was early. The accentuated lateral wall peak displacement correlated with the septal peak displacement time delay (r=0.60, p<0.001) and septal-lateral time delay (r=0.64, p<0.001) (Study III). In 21 surgical AVR patients who performed exercise echocardiography, the LV function was normal at rest but different from controls with exercise. At peak exercise, oxygen consumption (pVO2) was lower in patients than controls. Although patients could achieve cardiac output (CO) and heart rate (HR) similar to controls at peak exercise, the LV systolic and early diastolic myocardial velocities and strain rate as well as their delta changes were significantly lower than controls. pVO2 correlated with peak exercise LV myocardial function in the patients group only, and the systolic global longitudinal strain rate (GLSRs) at peak exercise was the only independent predictor of pVO2 in multivariate regression analysis (p=0.03) (Study IV).

Conclusion: Surgical AVR is an effective treatment for AS patients, but results in reversed septal radial motion and reduced TAPSE. The newly developed TAVI procedure maintains RV function which results in preservation of septal radial motion. In AS, the LV twist function is exaggerated, normalizes after AVR but loses its relationship with basal LV function. While the reversed septal motion results in decreased and delayed septal longitudinal displacement which is compensated for by the accentuated lateral wall displacement and the time early. These patients remain suffering from limited exercise capacity years after AVR.

sted, utgiver, år, opplag, sider
Umeå: Umeå universitet, 2011. s. 68
Serie
Umeå University medical dissertations, ISSN 0346-6612 ; 1442
Emneord
Aortic stenosis, aortic valve replacement, echocardiography, speckle tracking, exercise echocardiography, ventricular function, septal radial motion, twist, displacement, strain, strain rate
HSV kategori
Identifikatorer
urn:nbn:se:umu:diva-46809 (URN)978-91-7459-274-0 (ISBN)
Disputas
2011-10-14, sal 916, våning 9, UnodB9, Norrlands universitetssjukhus, Umeå, 09:00 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2011-09-23 Laget: 2011-09-15 Sist oppdatert: 2018-06-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Lindqvist, PerZhao, YingBajraktari, GaniHenein, Michael Y

Søk i DiVA

Av forfatter/redaktør
Lindqvist, PerZhao, YingBajraktari, GaniHenein, Michael Y
Av organisasjonen
I samme tidsskrift
Interactive Cardiovascular and Thoracic Surgery

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 196 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf