umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Effect evaluation of a heated ambulance mattress-prototype on thermal comfort and patients' temperatures in prehospital emergency care - an intervention study
Umeå universitet, Medicinska fakulteten, Institutionen för omvårdnad. Umeå universitet, Arktiskt centrum vid Umeå universitet (Arcum). (Arcum)
Umeå universitet, Medicinska fakulteten, Institutionen för omvårdnad.
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Kirurgi.
Umeå universitet, Medicinska fakulteten, Institutionen för omvårdnad. Umeå universitet, Arktiskt centrum vid Umeå universitet (Arcum). Center for Disaster Medicine, Umeå University, Umeå, Sweden. (Arcum)ORCID-id: 0000-0003-3716-6445
2015 (engelsk)Inngår i: International Journal of Circumpolar Health, ISSN 2242-3982, E-ISSN 2242-3982, Vol. 74, artikkel-id 28878Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: The ambulance milieu does not offer good thermal comfort to patients during the cold Swedish winters. Patients' exposure to cold temperatures combined with a cold ambulance mattress seems to be the major factor leading to an overall sensation of discomfort. There is little research on the effect of active heat delivered from underneath in ambulance care. Therefore, the aim of this study was to evaluate the effect of an electrically heated ambulance mattress-prototype on thermal comfort and patients' temperatures in the prehospital emergency care.

METHODS: A quantitative intervention study on ambulance care was conducted in the north of Sweden. The ambulance used for the intervention group (n=30) was equipped with an electrically heated mattress on the regular ambulance stretcher whereas for the control group (n=30) no active heat was provided on the stretcher. Outcome variables were measured as thermal comfort on the Cold Discomfort Scale (CDS), subjective comments on cold experiences, and finger, ear and air temperatures.

RESULTS: Thermal comfort, measured by CDS, improved during the ambulance transport to the emergency department in the intervention group (p=0.001) but decreased in the control group (p=0.014). A significant higher proportion (57%) of the control group rated the stretcher as cold to lie down compared to the intervention group (3%, p<0.001). At arrival, finger, ear and compartment air temperature showed no statistical significant difference between groups. Mean transport time was approximately 15 minutes.

CONCLUSIONS: The use of active heat from underneath increases the patients' thermal comfort and may prevent the negative consequences of cold stress.

sted, utgiver, år, opplag, sider
2015. Vol. 74, artikkel-id 28878
Emneord [en]
thermal comfort, thermal discomfort, finger temperature, cold exposure, Cold Discomfort Scale, cold stress, active heat, heat transfer
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-109969DOI: 10.3402/ijch.v74.28878ISI: 000369578900001PubMedID: 26374468OAI: oai:DiVA.org:umu-109969DiVA, id: diva2:859917
Tilgjengelig fra: 2015-10-09 Laget: 2015-10-09 Sist oppdatert: 2018-06-07bibliografisk kontrollert

Open Access i DiVA

fulltext(475 kB)467 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 475 kBChecksum SHA-512
a918b3d61fef9b0185b38c54a334fe10502dc3b6093b659d8ff4e9d59afe669c626fbe609f6ef6d63bbef8927102f599f65a08bccb4d2bc2bda8de75765df5bf
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Aléx, JonasKarlsson, StigBjörnstig, UlfSaveman, Britt-Inger

Søk i DiVA

Av forfatter/redaktør
Aléx, JonasKarlsson, StigBjörnstig, UlfSaveman, Britt-Inger
Av organisasjonen
I samme tidsskrift
International Journal of Circumpolar Health

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 467 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 979 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf