Umeå University's logo

umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Technical Note: MRI only prostate radiotherapy planning using the statistical decomposition algorithm
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper.
Vise andre og tillknytning
2015 (engelsk)Inngår i: Medical physics (Lancaster), ISSN 0094-2405, Vol. 42, nr 10, s. 6090-6097Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Purpose: In order to enable a magnetic resonance imaging (MRI) only workflow in radiotherapy treatment planning, methods are required for generating Hounsfield unit (HU) maps (i.e., synthetic computed tomography, sCT) for dose calculations, directly from MRI. The Statistical Decomposition Algorithm (SDA) is a method for automatically generating sCT images from a single MR image volume, based on automatic tissue classification in combination with a model trained using a multimodal template material. This study compares dose calculations between sCT generated by the SDA and conventional CT in the male pelvic region. Methods: The study comprised ten prostate cancer patients, for whom a 3D T2 weighted MRI and a conventional planning CT were acquired. For each patient, sCT images were generated from the acquired MRI using the SDA. In order to decouple the effect of variations in patient geometry between imaging modalities from the effect of uncertainties in the SDA, the conventional CT was nonrigidly registered to the MRI to assure that their geometries were well aligned. For each patient, a volumetric modulated arc therapy plan was created for the registered CT (rCT) and recalculated for both the sCT and the conventional CT. The results were evaluated using several methods, including mean average error (MAE), a set of dose-volume histogram parameters, and a restrictive gamma criterion (2% local dose/1 mm). Results: The MAE within the body contour was 36.5 +/- 4.1 (1 s.d.) HU between sCT and rCT. Average mean absorbed dose difference to target was 0.0% +/- 0.2% (1 s.d.) between sCT and rCT, whereas it was -0.3% +/- 0.3% (1 s.d.) between CT and rCT. The average gamma pass rate was 99.9% for sCT vs rCT, whereas it was 90.3% for CT vs rCT. Conclusions: The SDA enables a highly accurate MRI only workflow in prostate radiotherapy planning. The dosimetric uncertainties originating from the SDA appear negligible and are notably lower than the uncertainties introduced by variations in patient geometry between imaging sessions.

sted, utgiver, år, opplag, sider
2015. Vol. 42, nr 10, s. 6090-6097
Emneord [en]
MRI, radiotherapy, treatment planning, dose calculation, synthetic CT
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-111007DOI: 10.1118/1.4931417ISI: 000362570100053PubMedID: 26429284Scopus ID: 2-s2.0-84942893075OAI: oai:DiVA.org:umu-111007DiVA, id: diva2:868607
Tilgjengelig fra: 2015-11-11 Laget: 2015-11-02 Sist oppdatert: 2023-03-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Nyholm, TufveJonsson, Joakim

Søk i DiVA

Av forfatter/redaktør
Nyholm, TufveJonsson, Joakim
Av organisasjonen
I samme tidsskrift
Medical physics (Lancaster)

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 290 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf