umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A new way of assessing arm function in activity using kinematic Exposure Variation Analysis and portable inertial sensors - A validity study
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
2016 (engelsk)Inngår i: Manual Therapy, ISSN 1356-689X, E-ISSN 1532-2769, Vol. 21, s. 241-249Artikkel i tidsskrift (Fagfellevurdert) Published
Resurstyp
Text
Abstract [en]

Portable motion systems based on inertial motion sensors are promising methods, with the advantage compared to optoelectronic cameras of not being confined to a laboratory setting. A challenge is to develop relevant outcome measures for clinical use. The aim of this study was to characterize elbow and shoulder motion during functional tasks, using portable motion sensors and a modified Exposure Variation Analysis (EVA) and evaluate system accuracy with optoelectronic cameras. Ten healthy volunteers and one participant with sequel after stroke performed standardised functional arm tasks. Motion was registered simultaneously with a custom developed motion sensor system, including gyroscopes and accelerometers, and an optoelectronic camera system. The EVA was applied on elbow and shoulder joints, and angular and angular velocity EVA plots was calculated. The EVA showed characteristic patterns for each arm task in the healthy controls and a distinct difference between the affected and unaffected arm in the participant with sequel after stroke. The accuracy of the portable system was high with a systematic error ranging between -1.2 degrees and 2.0 degrees. The error was direction specific due to a drift component along the gravity vector. Portable motion sensor systems have high potential as clinical tools for evaluation of arm function. EVA effectively illustrates joint angle and joint angle velocity patterns that may capture deficiencies in arm function and movement quality. Next step will be to manage system drift by including magnetometers, to further develop clinically relevant outcome variables and apply this for relevant patient groups.

sted, utgiver, år, opplag, sider
2016. Vol. 21, s. 241-249
Emneord [en]
Upper extremity motion analysis, Portable motion sensors, Exposure Variation Analysis, Validity
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-120666DOI: 10.1016/j.math.2015.09.004ISI: 000373615100033PubMedID: 26456185OAI: oai:DiVA.org:umu-120666DiVA, id: diva2:938163
Tilgjengelig fra: 2016-06-16 Laget: 2016-05-18 Sist oppdatert: 2018-06-07bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Öhberg, FredrikGrip, Helena

Søk i DiVA

Av forfatter/redaktør
Öhberg, FredrikGrip, Helena
Av organisasjonen
I samme tidsskrift
Manual Therapy

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 333 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf