Energy Simulation and Analysis of an Intermittent Ventilation System Under Two Climates
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. (Building Energy Efficiency)
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: The 10th International Conference on Sustainable Energy and environmental Protection: Energy Efficiency, University of Maribor Press , 2017Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Energy use on heating, ventilation and air conditioning (HVAC) accounts for about 50% of total energy use in buildings. Energy efficient HVAC systems that do not compromise the indoor environmental quality and at the same time meet the energy reduction directives/policies are necessary and needed. The study herein, evaluates the energy saving potential of a newly proposed ventilation system in spaces with high occupancy density, called Intermittent Air Jet Strategy (IAJS). The aim of the study was to evaluate through simulations the potential energy savings due to IAJS as compared to a mixing ventilation (MV) system in a classroom located in a ‘hot and humid’ climate (Singapore), and in a ‘hot and dry’ climate (Kuwait). The analysis is based on IDA Indoor Climate Energy simulation software. The results herein demonstrate significant reduction of cooling energy use of up 54.5% for Singapore and up to 32.2% for Kuwait with IAJS as compared to MV. Additionally, supply fan energy savings can also be realized if well implemented.

Ort, förlag, år, upplaga, sidor
University of Maribor Press , 2017.
Nyckelord [en]
Intermittent air jets, Energy simulation, Energy saving, Setpoint extension, Convective cooling
Nationell ämneskategori
Husbyggnad
Identifikatorer
URN: urn:nbn:se:umu:diva-136579DOI: 10.18690/978-961-286-050-9ISBN: 978-961-286-050-9 (tryckt)OAI: oai:DiVA.org:umu-136579DiVA, id: diva2:1112247
Konferens
SEEP 2017 - 10th International Conference on Sustainable Energy & Environmental Protection, Bled, Slovenia, June 27-30, 2017
Tillgänglig från: 2017-06-20 Skapad: 2017-06-20 Senast uppdaterad: 2019-06-14Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Yang, Bin

Sök vidare i DiVA

Av författaren/redaktören
Yang, Bin
Av organisationen
Institutionen för tillämpad fysik och elektronik
Husbyggnad

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 96 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf