A randomized double-blind noninferiority trial, evaluating migration of a cemented vitamin E-stabilized highly crosslinked component compared with a standard polyethylene component in reverse hybrid total hip arthroplasty
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: The Bone & Joint Journal, ISSN 2049-4394, E-ISSN 2049-4408, Vol. 101-B, nr 10, s. 1192-1198Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

AIMS: Radiostereometric analysis (RSA) studies of vitamin E-doped, highly crosslinked polyethylene (VEPE) liners show low head penetration rates in cementless acetabular components. There is, however, currently no data on cemented VEPE acetabular components in total hip arthroplasty (THA). The aim of this study was to evaluate the safety of a new cemented VEPE component, compared with a conventional polyethylene (PE) component regarding migration, head penetration, and clinical results.

PATIENTS AND METHODS: We enrolled 42 patients (21 male, 21 female) with osteoarthritis and a mean age of 67 years (sd 5), in a double-blinded, noninferiority, randomized controlled trial. The subjects were randomized in a 1:1 ratio to receive a reverse hybrid THA with a cemented component of either argon-gas gamma-sterilized PE component (controls) or VEPE, with identical geometry. The primary endpoint was proximal implant migration of the component at two years postoperatively measured with RSA. Secondary endpoints included total migration of the component, penetration of the femoral head into the component, and patient-reported outcome measurements.

RESULTS: In total, 19 control implants and 18 implants in the VEPE group were analyzed for the primary endpoint. We found a continuous proximal migration of the component in the VEPE group that was significantly higher with a difference at two years of a mean 0.21 mm (95% confidence interval (CI) 0.05 to 0.37; p = 0.013). The total migration was also significantly higher in the VEPE group, but femoral head penetration was lower. We found no difference in clinical outcomes between the groups.

CONCLUSION: At two years, this cemented VEPE component, although having a low head penetration and excellent clinical results, failed to meet noninferiority compared with the conventional implant by a proximal migration above the proposed safety threshold of RSA. The early proximal migration pattern of the VEPE component is a reason for continued monitoring, although a specific threshold for proximal migration and risk for later failure cannot be defined and needs further study.

Ort, förlag, år, upplaga, sidor
The British Editorial Society of Bone & Joint Surgery , 2019. Vol. 101-B, nr 10, s. 1192-1198
Nyckelord [en]
Cemented component, Highly crosslinked polyethylene, Radiostereometry, Randomized clinical trial, Total hip arthroplasty, Vitamin E
Nationell ämneskategori
Ortopedi
Identifikatorer
URN: urn:nbn:se:umu:diva-163878DOI: 10.1302/0301-620X.101B10.BJJ-2019-0456.R2ISI: 000488617100005PubMedID: 31564144OAI: oai:DiVA.org:umu-163878DiVA, id: diva2:1358056
Forskningsfinansiär
Stockholms läns landstingTillgänglig från: 2019-10-07 Skapad: 2019-10-07 Senast uppdaterad: 2019-11-07Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Mukka, Sebastian

Sök vidare i DiVA

Av författaren/redaktören
Mukka, Sebastian
Av organisationen
Institutionen för kirurgisk och perioperativ vetenskap
I samma tidskrift
The Bone & Joint Journal
Ortopedi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 20 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf