Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparison of Modified Double Tray Method and 3D scanning i prosthodontics
Umeå universitet, Medicinska fakulteten, Institutionen för odontologi.
Umeå universitet, Medicinska fakulteten, Institutionen för odontologi.
2023 (Engelska)Självständigt arbete på avancerad nivå (masterexamen), 20 poäng / 30 hpStudentuppsats (Examensarbete)
Abstract [en]

The purpose of this in vitro study was to investigate and to compare the precision of two different impression techniques for oral prosthetic construction, namely the analogue modified double tray method, and the digital three-dimensional scanning with Trios 3D shape intraoral scanner. The analog method used was a modified double tray method where the tray had been removed to diminish vertical discrepancies in occlusion. All testing was based on a master model with a prepared acrylic tooth from which a total of 20 milled crowns in polymethylmethacrylate was produced, 10 from each impression method.  The fit of the crowns was evaluated according to a clinical protocol and the cement gap was measured with a measuring microscope. Each crown was fitted on to the master model with Flexitime light body, mimicking a cementing procedure. The resulting “cement layer” was after setting of the silicone impression material removed and divided into 4 equal pieces which subsequently were measured in a measuring microscope. Statistical analysis of the resulting measurements showed no significant differences in precision when comparing the impression methods. Because of a manufacturing error in the milling procedure, all of the milled plastic crowns showed suboptimal fit on the master model. However, it was concluded that no statistical - nor clinical difference between the two methods could be established. Most likely, both methods can be used for fabrication of single unit prosthetic reconstructions with adequate precision for effective treatment. 

Ort, förlag, år, upplaga, sidor
2023.
Nyckelord [en]
3D scanning, modified double tray method.
Nationell ämneskategori
Odontologi
Identifikatorer
URN: urn:nbn:se:umu:diva-218193OAI: oai:DiVA.org:umu-218193DiVA, id: diva2:1820629
Externt samarbete
Region Västerbotten
Utbildningsprogram
Tandläkarprogrammet
Handledare
Examinatorer
Tillgänglig från: 2023-12-18 Skapad: 2023-12-18 Senast uppdaterad: 2023-12-18Bibliografiskt granskad

Open Access i DiVA

fulltext(208 kB)66 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 208 kBChecksumma SHA-512
2db86b548e221cae75cf025584acf75eb3f830ef6fda4d2695accf1266e64b240ae3627737f2e867b3852c47ef61d956955c34d98eac59ad365b4795320b0a41
Typ fulltextMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Nermo, ElsaRousseau, Eloïse
Av organisationen
Institutionen för odontologi
Odontologi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 66 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 161 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf