Umeå universitets logga

umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Kriterievaliditet för Cooper 12 min run test och Ekblom-Bak test för uthållighetsidrottare
Umeå universitet, Medicinska fakulteten, Institutionen för samhällsmedicin och rehabilitering, Avdelningen för idrottsmedicin.
Umeå universitet, Medicinska fakulteten, Institutionen för samhällsmedicin och rehabilitering, Avdelningen för idrottsmedicin.
2024 (Svenska)Självständigt arbete på grundnivå (kandidatexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)Alternativ titel
Criterion validity for Cooper 12 min run test and Ekblom-Bak test for endurance athletes (Engelska)
Abstract [sv]

Bakgrund: Aerob kapacitet är en viktig fysiologisk egenskap och kan mätas genom maximala- och submaximala tester. Ekblom-Bak testet (EB-testet) är ett submaximalt cykeltest medan Cooper 12 min test (CRT-12) är ett maximalt test, men dem båda uppskattar maximal syreupptagningsförmåga (VO2max) genom matematiska formler. Det finns fördelar med estimerade tester i idrottsvärlden, men tillförlitligheten varierar. Syftet var att undersöka validiteten av EB-testet och CRT-12 genom kriterievaliditet för ett urval av uthållighetsidrottare. Vidare syftar studien till att undersöka om det sker en eventuell över- eller underestimering av EB-testresultat och av CRT-12 testresultat.

Metod: De rekryterade studiedeltagarna var åtta uthållighetsidrottare inom olika uthållighetsidrotter. Studien bestod av två testtillfällen. Vid första testtillfället genomfördes EB-test och ett VO2max test. Under andra testtillfället genomförde CRT-12. Uppmätt relativt syreupptag ställdes mot estimerade värden genom Bland-Altman analys och Interklass korrelation koefficient (ICC).

Resultat: EB-testet hade måttlig överensstämmelse med ICC värde av 0,57. CRT-12 hade god överensstämmelse med ICC värde av 0,75. Både mätmetoderna överestimerade resultat vid jämförelse mot kriteriemetoden. 

Konklusion: För studiens urval ansågs CRT-12 ge mer tillförlitliga resultat än EB-testet. För att kunna möjliggöra generalisering av resultatet behövs vidare forskning med en större urvalsgrupp av studiedeltagare.

Abstract [en]

Background: Aerobic capacity is a physiological component which can be measured through maximal- and submaximal tests. The Ekblom-Bak test (EB-test) is a submaximal cycle test whereas Cooper 12 min run test (CRT-12) is a maximal test, but they both estimate maximal oxygen consumption (VO2max) through mathematical formulas. There are advantages of estimated testing methods in the sports world, but reliability varies. The study aims to investigate the validity of the EB-test and the CRT-12 through criterion validity for a sample of endurance athletes. Further the study aims to investigate if there occurs an over- or under estimation of the EB-test results and of the CRT-12 results.

Method: The recruited participants where eight endurance athletes from various sports. The study consisted of two test occasions. The first occasion consisted of the EB-test and the VO2max test. The second occasion consisted of the CRT-12. Measured relative oxygen consumption was opposed to the estimated values through a Bland-Altman plot and a interclass corelation coefficient (ICC).

Results: The Ekblom-bak test was seen to have moderate agreement with an ICC of 0,57. The cooper 12 min run test was seen to have good agreement with an ICC of 0,75. Both tests overestimated the results when compared to the criterion method.

Conclusion: For the population of the study, it was seen that CRT-12 is more reliable than the EB-test. To be able to generalise the results there is a need for further research with a larger study population. 

Ort, förlag, år, upplaga, sidor
2024. , s. 45
Nyckelord [en]
Aerobic capacity, indirect calorimetry, validity and oxygen uptake measurement
Nyckelord [sv]
Aerob kapacitet, indirekt kalorimetri, validitet och syreupptagningsmätning
Nationell ämneskategori
Idrottsvetenskap och fitness
Identifikatorer
URN: urn:nbn:se:umu:diva-227048OAI: oai:DiVA.org:umu-227048DiVA, id: diva2:1878317
Ämne / kurs
Examensarbete för kandidatexamen i idrottsmedicin
Utbildningsprogram
Idrottsfysiologprogrammet - idrottsmedicin, prestation och hälsa
Handledare
Examinatorer
Tillgänglig från: 2024-06-28 Skapad: 2024-06-26 Senast uppdaterad: 2025-02-11Bibliografiskt granskad

Open Access i DiVA

fulltext(1699 kB)117 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1699 kBChecksumma SHA-512
2cc5368e9ca4bbae303493cd11ecc627bf337b7c96506b1032b896ba20bda819afb2ad9d5ad30b2bc5201cb71d33a25fb396c3d6c3b008172df93e5b437d5bcc
Typ fulltextMimetyp application/pdf

Av organisationen
Avdelningen för idrottsmedicin
Idrottsvetenskap och fitness

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 117 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 396 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf