Aspects of alkali chloride chemistry on deposit formation and high temperature corrosion in biomass and waste fired boilers
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik, Energiteknik och termisk processkemi.ORCID-id: 0000-0003-1095-9154
2010 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Combustion of biomass and waste has several environmental, economical and political advantages over the use of fossil fuels for the generation of heat and electricity. However, these fuels often have a significantly different composition and the combustion is therefore associated with additional operational problems. A high content of chlorine and alkali metals (potassium and sodium) often causes problems with deposit formation and high temperature corrosion. Some different aspects of these issues are addressed in this thesis.

The overall objective of this thesis was to study and highlight different means by which operational problems related to alkali chlorides can be overcome, reduced or prevented.

The most important results of this thesis are: (1) A full description of the in-situ alkali chloride monitor, its operational principles, the calibration procedure, and an example of a full-scale application was made public in a scientific publication. (2) Efficient sulfation of gaseous alkali chlorides in a full-scale boiler was achieved by injecting ammonium sulfate in a water solution into the hot flue gas. (3) Reduced deposit growth and corrosion rates were achieved by lowering the alkali chloride concentration in the flue gas by sulfation. (4) Evidence of decreased deposit growth and chlorine content in deposits during peat co-combustion. (5) Results are presented from high temperature corrosion tests with different superheater steels in two different combustion environments. (6) Controlled KCl and NaCl condensation under simulated combustion conditions resulted in deposits which consisted of mostly pure phases, in contrast to the solid solution that would be expected under the prevailing conditions at chemical equilibrium.

Ort, förlag, år, upplaga, sidor
Umeå: Umeå universitet, Institutionen för tillämpad fysik och elektronik, avdelningen energiteknik och termisk processkemi , 2010. , s. 45
Serie
ETPC Report, ISSN 1653-0551 ; 10-04
Nationell ämneskategori
Fysik
Forskningsämne
fysik; elektronik
Identifikatorer
URN: urn:nbn:se:umu:diva-33667ISBN: 978-91-7459-009-8 (tryckt)OAI: oai:DiVA.org:umu-33667DiVA, id: diva2:317028
Disputation
2010-06-01, Naturvetarhuset, M450, Umeå University, Umeå, 13:00 (Engelska)
Opponent
Handledare
Tillgänglig från: 2010-05-07 Skapad: 2010-04-30 Senast uppdaterad: 2018-06-08Bibliografiskt granskad
Delarbeten
1. Sulfation of corrosive alkali chlorides by ammonium sulfate in a biomass fired CFB boiler
Öppna denna publikation i ny flik eller fönster >>Sulfation of corrosive alkali chlorides by ammonium sulfate in a biomass fired CFB boiler
Visa övriga...
2007 (Engelska)Ingår i: Fuel processing technology, ISSN 0378-3820, E-ISSN 1873-7188, Vol. 88, nr 11-12, s. 1171-1177Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Biomass and waste derived fuels contain relatively high amounts of alkali and chlorine, but contain very little sulfur. Combustion of such fuels can result in increased deposit formation and superheater corrosion. These problems can be reduced by using a sulfur containing additive, such as ammonium sulfate, which reacts with the alkali chlorides and forms less corrosive sulfates. Ammonium sulfate injection together with a so-called in situ alkali chloride monitor (IACM) is patented and known as "ChlorOut". IACM measures the concentrations of alkali chlorides (mainly KCl in biomass combustion) at superheater temperatures. Tests with and without spraying ammonium sulfate into the flue gases have been performed in a 96MW(th)/25MW(e) circulating fluidized bed (CFB) boiler. The boiler was fired mainly with bark and a chlorine containing waste. KCl concentration was reduced from more than 15 ppm to approximately 2 ppm. during injection of ammonium sulfate. Corrosion probe measurements indicated that both deposit formation and material loss due to corrosion were decreased using the additive. Analysis of the deposits showed significantly higher concentration of sulfur and almost no chlorine in the case with ammonium sulfate. Results from impactor measurements supported that KCl was sulfated to potassium sulfate by the additive. (C) 2007 Elsevier B.V. All rights reserved.

Ort, förlag, år, upplaga, sidor
Amsterdam: Elsevier Bv, 2007
Nyckelord
biomass combustion, high temperature corrosion, sulfation, kcl, chlorout, iacm, combustion
Identifikatorer
urn:nbn:se:umu:diva-19737 (URN)10.1016/j.fuproc.2007.06.023 (DOI)0378-3820 (ISBN)
Tillgänglig från: 2009-03-10 Skapad: 2009-03-10 Senast uppdaterad: 2018-06-09Bibliografiskt granskad
2. High temperature corrosion in a 65 MW waste to energy plant
Öppna denna publikation i ny flik eller fönster >>High temperature corrosion in a 65 MW waste to energy plant
Visa övriga...
2007 (Engelska)Ingår i: Fuel processing technology, ISSN 0378-3820, E-ISSN 1873-7188, Vol. 88, nr 11-12, s. 1178-1182Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Incineration of municipal solid waste is often associated with high temperature corrosion problems. This paper presents results of full-scale corrosion tests in a 65 MW waste fired combined heat and power plant. A failure case indicated alarmingly high corrosion rate of the superheater tubes. Corrosion tests with five different alloys were carried out within this work in order to determine plant specific corrosion rates on different superheater materials. Additional tests were done to determine the effect on the corrosion rate from adding chlorine containing polyvinyl chloride to the ordinary fuel mix. A corrosion probe with metal temperatures ranging from 320 degrees C to 460 degrees C was used to estimate corrosion loss and to collect deposits. The sampling was performed at a flue gas temperature of 470 degrees C for 10 days. The probe rings were analysed using scanning electron microscope and micrometer measurements to determine the deposit chemistry and corrosion rates. The results showed significant differences in corrosion rates depending on tube material. Chlorine was shown to have a key role in the corrosion process, even at these relatively low temperatures. The results indicated a chlorine induced corrosion mechanism involving volatile iron chloride with a high corrosion rate on the superheater materials typically used. Addition of extra polyvinyl chloride to the fuel mix had an increasing effect on the corrosion. (C) 2007 Elsevier B.V. All rights reserved.

Ort, förlag, år, upplaga, sidor
Elsevier B.V., 2007
Nyckelord
superheater corrosion, waste incineration, pvc, msw, chlorine
Identifikatorer
urn:nbn:se:umu:diva-19744 (URN)10.1016/j.fuproc.2007.06.031 (DOI)0378-3820 (ISBN)
Anmärkning
This work was supported by Umeå Energi AB. Technical assistance by Vattenfall Research and Development AB is also acknowledged. Tillgänglig från: 2009-03-10 Skapad: 2009-03-10 Senast uppdaterad: 2018-06-09Bibliografiskt granskad
3. Principle, calibration, and application of the in situ alkali chloride monitor
Öppna denna publikation i ny flik eller fönster >>Principle, calibration, and application of the in situ alkali chloride monitor
Visa övriga...
2009 (Engelska)Ingår i: Review of Scientific Instruments, ISSN 0034-6748, E-ISSN 1089-7623, Vol. 80, nr 2, s. 023104-1-023104-4Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

 The extended use of biomass for heat and power production has caused increased operational problems with fouling and high-temperature corrosion in boilers. These problems are mainly related to the presence of alkali chlorides (KCl and NaCl) at high concentrations in the flue gas. The In-Situ Alkali Chloride Monitor (IACM) was developed by Vattenfall Research and Development AB for measuring the alkali chloride concentration in hot flue gases (>650 oC). The measurement technique is based on molecular differential absorption spectroscopy in the UV range. Simultaneous measurement of SO2 concentration is also possible. The measuring range is 1-50 ppm for the sum of KCl and NaCl concentrations, and 4-750 ppm for SO2. This paper describes the principle of the IACM as well as its calibration. Furthermore, an example of its application in an industrial boiler is given.

Ort, förlag, år, upplaga, sidor
American Institute of Physics, 2009
Nyckelord
bioenergy conversion, boilers, corrosion, flue gases, gas sensors, ultraviolet spectra
Identifikatorer
urn:nbn:se:umu:diva-19738 (URN)10.1063/1.3081015 (DOI)
Tillgänglig från: 2009-03-10 Skapad: 2009-03-10 Senast uppdaterad: 2018-06-09Bibliografiskt granskad

Open Access i DiVA

fulltext(1807 kB)11367 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1807 kBChecksumma SHA-512
d81356a18b373575a2e73636eb1decf7bead8892e70a5f7f8feb2dacb2a747e4231c157eeb07b5546b2d5bd42359c211af251d7abc775e36e5072b3c3b2982c7
Typ fulltextMimetyp application/pdf

Personposter BETA

Broström, Markus

Sök vidare i DiVA

Av författaren/redaktören
Broström, Markus
Av organisationen
Energiteknik och termisk processkemi
Fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 11367 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 1384 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf