umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparison of glistenings in intraocular lenses with three different materials: 12-year follow-up
Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.
Visa övriga samt affilieringar
2013 (Engelska)Ingår i: Acta Ophthalmologica, ISSN 1755-375X, E-ISSN 1755-3768, Vol. 91, nr 1, s. 66-70Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose:  To compare the degree of lens glistenings associated with three intraocular lenses (IOLs) of different materials and examine the relationship between the dioptric power of the optics and lens glistenings in a long-term study. Setting:  St. Erik Eye Hospital, Stockholm, Sweden. Methods:  Forty-six eyes of 46 patients underwent standard phacoemulsification and implantation with a heparin-surface-modified (HSM) polymethylmethacrylate (PMMA) IOL, a silicone IOL or a hydrophobic acrylic IOL. Evaluations of the patients and the glistenings were conducted 11.3-13.4 years postoperatively. The glistenings were examined using Scheimpflug imaging and subsequently analysed using an image analysis program. Results:  The median follow-up time was 12.2 years (range, 11.3-13.4). The hydrophobic acrylic IOL had significantly more lens glistenings than the silicone (p = 0.003) and the PMMA (p = 0.000) IOLs. The silicone IOL had significantly more lens glistenings than the PMMA lens (p = 0.048). The IOL power did not affect the degree of lens glistenings in the hydrophobic acrylic IOL group (p = 0.64). The other groups had too little lens glistenings to evaluate the relationship. Conclusion:  In this long-term follow-up study, the hydrophobic acrylic IOL had a significantly higher degree of lens glistenings compared to the silicone and PMMA IOLs. The PMMA IOL had almost no lens glistenings. The IOL dioptric power was not significantly correlated with the degree of lens glistenings associated with the hydrophobic acrylic IOL.

Ort, förlag, år, upplaga, sidor
Wiley-Blackwell, 2013. Vol. 91, nr 1, s. 66-70
Nyckelord [en]
acrylic, dioptric power, glistenings, hydrophobic, intraocular lens, material, polymethylmethacrylate, silicone
Nationell ämneskategori
Oftalmologi
Identifikatorer
URN: urn:nbn:se:umu:diva-55121DOI: 10.1111/j.1755-3768.2011.02277.xPubMedID: 22035345OAI: oai:DiVA.org:umu-55121DiVA, id: diva2:525654
Anmärkning

Article first published online: 28 OCT 2011

Tillgänglig från: 2012-05-08 Skapad: 2012-05-08 Senast uppdaterad: 2018-06-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Behndig, Anders

Sök vidare i DiVA

Av författaren/redaktören
Behndig, Anders
Av organisationen
Oftalmiatrik
I samma tidskrift
Acta Ophthalmologica
Oftalmologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 129 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf