Thermal comfort, perceived air quality and cognitive performance when personally controlled air movement is used by tropically acclimatized persons
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. School of Civil and Environmental Engineering, Nanyang Technological University, Singapore; Berkeley Education Alliance for Research in Singapore, Singapore. (Building Energy Efficiency)
Vise andre og tillknytning
2017 (engelsk)Inngår i: Indoor Air, ISSN 0905-6947, E-ISSN 1600-0668, Vol. 27, nr 3, s. 690-702Artikkel i tidsskrift, Editorial material (Fagfellevurdert) Published
Abstract [en]

In a warm and humid climate, increasing the temperature set point offers considerable energy benefits with low first costs. Elevated air movement generated by a personally controlled fan can compensate for the negative effects caused by an increased temperature set point. Fifty-six tropically acclimatized persons in common Singaporean office attire (0.7 clo) were exposed for 90 minutes to each of five conditions: 23, 26, and 29°C and in the latter two cases with and without occupant-controlled air movement. Relative humidity was maintained at 60%. We tested thermal comfort, perceived air quality, sick building syndrome symptoms, and cognitive performance. We found that thermal comfort, perceived air quality, and sick building syndrome symptoms are equal or better at 26°C and 29°C than at the common set point of 23°C if a personally controlled fan is available for use. The best cognitive performance (as indicated by task speed) was obtained at 26°C; at 29°C, the availability of an occupant-controlled fan partially mitigated the negative effect of the elevated temperature. The typical Singaporean indoor air temperature set point of 23°C yielded the lowest cognitive performance. An elevated set point in air-conditioned buildings augmented with personally controlled fans might yield benefits for reduced energy use and improved indoor environmental quality in tropical climates.

sted, utgiver, år, opplag, sider
2017. Vol. 27, nr 3, s. 690-702
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-128006DOI: 10.1111/ina.12352ISI: 000399681800019PubMedID: 27754563OAI: oai:DiVA.org:umu-128006DiVA, id: diva2:1048627
Tilgjengelig fra: 2016-11-21 Laget: 2016-11-21 Sist oppdatert: 2018-06-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Yang, Bin

Søk i DiVA

Av forfatter/redaktør
Yang, Bin
Av organisasjonen
I samme tidsskrift
Indoor Air

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 186 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf