Simulator training and non-technical factors improve laparoscopic performance among OBGYN trainees
Visa övriga samt affilieringar
2013 (Engelska)Ingår i: Acta Obstetricia et Gynecologica Scandinavica, ISSN 0001-6349, E-ISSN 1600-0412, Vol. 92, nr 10, s. 1194-1201Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

OBJECTIVE: To investigate how simulator training and non-technical factors affect laparoscopic performance among residents in obstetrics and gynecology. DESIGN: In this prospective study, trainees were randomized into three groups. The first group was allocated to proficiency-based training in the LapSimGyn(®) virtual reality simulator. The second group received additional structured mentorship during subsequent laparoscopies. The third group served as control group. At baseline an operation was performed and visuospatial ability, flow and self-efficacy were assessed. All groups subsequently performed three tubal occlusions. Self-efficacy and flow were assessed before and/or after each operation. SETTING: Simulator training was conducted at the Center for Advanced Medical Simulation and Training, Karolinska University Hospital. Sterilizations were performed at each trainee's home clinic. POPULATION: Twenty-eight trainees/residents from 21 hospitals in Sweden were included. METHODS/MAIN OUTCOME MEASURES: Visuospatial ability was tested by the Mental Rotation Test-A. Flow and self-efficacy were assessed by validated scales and questionnaires. Laparoscopic performance was measured as the duration of surgery. Visuospatial ability, self-efficacy and flow were correlated to the laparoscopic performance using Spearman's correlations. Differences between groups were analyzed by the Mann-Whitney U-test. RESULTS: No differences across groups were detected at baseline. Self-efficacy scores before and flow scores after the third operation were significantly higher in the trained groups. Duration of surgery was significantly shorter in the trained groups. Flow and self-efficacy correlate positively with laparoscopic performance. CONCLUSIONS: Simulator training and non-technical factors appear to improve the laparoscopic performance among trainees/residents in obstetrics and gynecology.

Ort, förlag, år, upplaga, sidor
Wiley-Blackwell, 2013. Vol. 92, nr 10, s. 1194-1201
Nyckelord [en]
Laparoscopic surgery, flow, obstetrics and gynecology, residents, self-efficacy, simulator training, visuospatial ability
Nationell ämneskategori
Reproduktionsmedicin och gynekologi Kirurgi
Identifikatorer
URN: urn:nbn:se:umu:diva-132486DOI: 10.1111/aogs.12218ISI: 000325081400012PubMedID: 24461067OAI: oai:DiVA.org:umu-132486DiVA, id: diva2:1081768
Tillgänglig från: 2017-03-15 Skapad: 2017-03-15 Senast uppdaterad: 2018-06-09Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Enochsson, Lars

Sök vidare i DiVA

Av författaren/redaktören
Enochsson, Lars
Av organisationen
Kirurgi
I samma tidskrift
Acta Obstetricia et Gynecologica Scandinavica
Reproduktionsmedicin och gynekologiKirurgi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 1156 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf