Occupants' perception of air movements and air quality in a simulated classroom with an intermittent air supply system
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. (Building Energy Efficiency)
2019 (engelsk)Inngår i: Indoor + Built Environment, ISSN 1420-326X, E-ISSN 1423-0070, Vol. 28, nr 1, s. 63-76Artikkel i tidsskrift, Editorial material (Fagfellevurdert) Published
Abstract [en]

The study reported herein builds on occupant response to an intermittent air jet strategy (IAJS), which creates periodic airflow and non-isothermal conditions in the occupied zone. Previous research has highlighted benefits of IAJS for the thermal climate and energy saving potential in view of human thermal perception of the indoor environment. The study herein explores the occupant acceptability of air movements and perceived indoor air quality. Thirty-six participants were exposed to three room air temperatures (nominal: 22.5℃, 25.5℃ and 28.5℃) with each having four air speed conditions (nominal: < 0.15 m/s under mixing ventilation (MV) and 0.4, 0.6 and 0.8 m/s under IAJS) measured at the breathing height (1.1 m). The results show that participants preferred low air movements at lower temperatures and high air movements at higher temperatures. A model to predict percentage satisfied with intermittent air movements was developed. The model predicts that 87% of occupants, in compliance with ASHRAE 55-2013 standard, will find intermittent air movements acceptable between 23.7℃ and 29.1℃ within an air speed range of 0.4 to 0.8 m/s. IAJS also improved participants' perception of air quality in conditions deemed poor under MV. The findings support the potential of IAJS as a primary ventilation system in high occupant spaces such as classrooms.

sted, utgiver, år, opplag, sider
Sage Publications, 2019. Vol. 28, nr 1, s. 63-76
Emneord [en]
Intermittent air jets, Air movement acceptability, Perceived air quality, High occupant density
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-139730DOI: 10.1177/1420326X17732613ISI: 000454140000006OAI: oai:DiVA.org:umu-139730DiVA, id: diva2:1143100
Merknad

Article first published online: September 20, 2017.

Tilgjengelig fra: 2017-09-20 Laget: 2017-09-20 Sist oppdatert: 2019-01-15bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Yang, Bin

Søk i DiVA

Av forfatter/redaktør
Yang, Bin
Av organisasjonen
I samme tidsskrift
Indoor + Built Environment

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 185 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf