This work presents an extension of a design procedure for dynamic output feedback design for systems with nonlinearities satisfying quadratic constraints. In this work we used an axial gas compressor model described by the 3-state Moore-Greitzer compressor model (MG) that has some challenges for output feedback control design (Planovsky and Nikolaev 1990), (Rubanova 2013). The more general constraints for the investigation of the robustness with respect to parametric uncertainties and measurement noise are shown.
Issue 3