All-polyethylene tibial components in young patients have stable fixation; a comparison RSA study
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Ortopedi.
2019 (engelsk)Inngår i: Knee (Oxford), ISSN 0968-0160, E-ISSN 1873-5800, Vol. 26, nr 2, s. 392-399Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: All-polyethylene (AP) tibial components in patients aged greater than 60 years have stable tibial migration patterns and favorable survival rates when compared to identical Metal-backed (MB) designs. Tibial component migration in younger patients has not been reported. The aim of this study was to examine the migration characteristics of patients aged less than 60 years compared to a previous cohort of AP and MB tibial components of identical design in older patients.

METHODS: A prospective consecutive study examined tibial component migration in 21 patients aged less than 60 years undergoing a cemented total knee arthroplasty with an AP tibial component by radiostereometric analysis (RSA) to 24 months. Results were compared to the authors' previous series of 21 patients aged greater than 60 years that were randomized to either an AP or MB tibial component.

RESULTS: Both age groups of patients implanted with an AP component had stable migration patterns with no patient having greater than 0.2° rotation or 0.2 mm maximum total point motion. Five of 11 MB tibial components displayed continued migration between one and two years. Subsidence was similar in all groups, whilst maximum total point motion was greater for the MB cohort (0.34 mm, 0.33 mm, 0.61 mm; AP <60, AP >60, MB).

CONCLUSIONS: Young patients implanted with an AP tibial component had stable tibial migration patterns comparable to older patients with the same AP implant. Regardless of age, AP tibial components were at least as stable as MB tibial components.

LEVEL OF EVIDENCE: Level II, Prospective comparative study.

sted, utgiver, år, opplag, sider
Elsevier, 2019. Vol. 26, nr 2, s. 392-399
Emneord [en]
All-polyethylene, Knee arthroplasty, Radiostereometry, Tibial migration
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-157680DOI: 10.1016/j.knee.2018.12.003ISI: 000470052400014PubMedID: 30638681OAI: oai:DiVA.org:umu-157680DiVA, id: diva2:1300743
Tilgjengelig fra: 2019-03-29 Laget: 2019-03-29 Sist oppdatert: 2019-06-20bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Nilsson, Kjell G.

Søk i DiVA

Av forfatter/redaktør
Nilsson, Kjell G.
Av organisasjonen
I samme tidsskrift
Knee (Oxford)

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 129 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf