umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Methods for estimating uptake and absorbed dose in tumours from I-125 labelled monoclonal antibodies, based on scintigraphic imaging of mice.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Diagnostisk radiologi.
1999 (Engelska)Ingår i: Acta Oncologica, ISSN 0284-186X, E-ISSN 1651-226X, Vol. 38, nr 3, s. 361-365Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Monoclonal antibodies for radioimmunotargeting are often tested in tumour bearing nude mice. In vivo determination of the uptake of the monoclonal antibody in the tumour requires quantitative scintigraphy, and this in turn requires an adequate method for subtraction of radiation from the normal tissue. For this reason, two different methods for background subtraction were evaluated, a contralateral background region of interest or an irregular one, surrounding the tumour. A pinhole collimator was used for the scintigraphy and the monoclonal antibodies were labelled with 125I. Furthermore, a method was developed for estimation of the mean absorbed dose in the tumour from these repeated quantitative scintigraphic measurements. This requires that the tumour mass can be accurately estimated in vivo. Finally, the results were compared with in vitro measurements of the uptake.

Ort, förlag, år, upplaga, sidor
1999. Vol. 38, nr 3, s. 361-365
Identifikatorer
URN: urn:nbn:se:umu:diva-4822DOI: 10.1080/028418699431447PubMedID: 10380828OAI: oai:DiVA.org:umu-4822DiVA, id: diva2:144071
Tillgänglig från: 2005-11-17 Skapad: 2005-11-17 Senast uppdaterad: 2018-06-09Bibliografiskt granskad
Ingår i avhandling
1. Corrections for improved quantitative accuracy in SPECT and planar scintigraphic imaging
Öppna denna publikation i ny flik eller fönster >>Corrections for improved quantitative accuracy in SPECT and planar scintigraphic imaging
2005 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

A quantitative evaluation of single photon emission computed tomography (SPECT) and planar scintigraphic imaging may be valuable for both diagnostic and therapeutic purposes. For an accurate quantification it is usually necessary to correct for attenuation and scatter and in some cases also for septal penetration. For planar imaging a background correction for the contribution from over- and underlying tissues is needed. In this work a few correction methods have been evaluated and further developed. Much of the work relies on the Monte Carlo method as a tool for evaluation and optimisation.

A method for quantifying the activity of I-125 labelled antibodies in a tumour inoculated in the flank of a mouse, based on planar scintigraphic imaging with a pin-hole collimator, has been developed and two different methods for background subtraction have been compared. The activity estimates of the tumours were compared with measurements in vitro.

The major part of this work is attributed to SPECT. A method for attenuation and scatter correction of brain SPECT based on computed tomography (CT) images of the same patient has been developed, using an attenuation map calculated from the CT image volume. The attenuation map is utilised not only for attenuation correction, but also for scatter correction with transmission dependent convolution subtraction (TDCS). A registration method based on fiducial markers, placed on three chosen points during the SPECT examination, was evaluated.

The scatter correction method, TDCS, was then optimised for regional cerebral blood flow (rCBF) SPECT with Tc-99m, and was also compared with a related method, convolution scatter subtraction (CSS). TDCS has been claimed to be an iterative technique. This requires however some modifications of the method, which have been demonstrated and evaluated for a simulation with a point source.

When the Monte Carlo method is used for evaluation of corrections for septal penetration, it is important that interactions in the collimator are taken into account. A new version of the Monte Carlo program SIMIND with this capability has been evaluated by comparing measured and simulated images and energy spectra. This code was later used for the evaluation of a few different methods for correction of scatter and septal penetration of I-123 brain SPECT. The methods were CSS, TDCS and a method where correction for scatter and septal penetration are included in the iterative reconstruction. This study shows that quantitative accuracy in I-123 brain SPECT benefits from separate modelling of scatter and septal penetration.

Ort, förlag, år, upplaga, sidor
Umeå: Umeå universitet, 2005. s. 88
Serie
Umeå University medical dissertations, ISSN 0346-6612 ; 983
Nyckelord
Quantitative SPECT, scintigraphic imaging, attenuation correction, scatter correction, collimator-detector response, septal penetration, background correction, Monte Carlo simulation
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
urn:nbn:se:umu:diva-636 (URN)91-7305-938-2 (ISBN)
Disputation
2005-12-09, 244, 7, Norrlands Universitetssjukhus, Umeå, 13:00 (Engelska)
Opponent
Handledare
Tillgänglig från: 2005-11-17 Skapad: 2005-11-17 Senast uppdaterad: 2018-06-09Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Larsson, AnneJohansson, LennartRiklund Åhlström, Katrine

Sök vidare i DiVA

Av författaren/redaktören
Larsson, AnneJohansson, LennartRiklund Åhlström, Katrine
Av organisationen
RadiofysikDiagnostisk radiologi
I samma tidskrift
Acta Oncologica

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 182 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf