Corrosion of dental nickel-aluminum bronze with a minor gold content-mechanism and biological impact
Umeå universitet, Medicinska fakulteten, Institutionen för odontologi.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen.
2009 (Engelska)Ingår i: Journal of Biomedical Materials Research. Part B - Applied biomaterials, ISSN 1552-4973, E-ISSN 1552-4981, Vol. 88B, nr 2, s. 465-473Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objectives: To study corrosion and to evaluate biological effects in vitro of corrosion products of a copper-aluminum-nickel alloy with 2% gold. Methods: The alloy NPGTM+2 with the nominal composition Cu:77.3; Al:7.8; Ni:4.3; Fe:3.0; Zn:2.7; Au:2.0; and Mn:1.7 was characterized. Static immersion in acidic saline, pH 2.2-2.4, was used to determine release of metallic elements in a milieu simulating the condition of plaque build-up in interproximal areas of the tooth. Corrosion and surface reactions in saline and artificial saliva were studied by electrochemical techniques including registration of open-circuit-potentials, polarization curves and impedance spectra. Extracts were made in cell culture media and acidic saline and used for MTT test for cytotoxicity and HET-CAM method for irritation. Results: The mean amount of elements released in the acidic saline were in g cm-2 : Cu:632; Al:210; Ni:144; Fe:122; Zn:48; Mn:52. No protective film was formed on the surface of the alloy, as extensive corrosion was observed in both saline and artificial saliva. The corrosion rate was higher in saline than in artificial saliva. Acidic extracts of the alloy diluted up to 64 times reduced cell viability with 80% or more. The extract induced coagulation of the blood vessels of the CAM and was rated as moderate irritant solution. Significance: The nickel-aluminum bronze showed high corrosion rate caused by an inability to create a protective surface layer. High levels of toxic elements were found after static immersion testing, and the corrosion products had a distinct adverse effect on the biological activity.

Ort, förlag, år, upplaga, sidor
Malden: Wiley-Blackwell, 2009. Vol. 88B, nr 2, s. 465-473
Nyckelord [en]
alloy, copper, aluminum, gold, corrosion, cell culture, cytotoxicity, HET-CAM, irritant, biocompatibility
Nationell ämneskategori
Odontologi
Identifikatorer
URN: urn:nbn:se:umu:diva-10117DOI: 10.1002/jbm.b.31143ISI: 000262683900020PubMedID: 18546197OAI: oai:DiVA.org:umu-10117DiVA, id: diva2:149788
Tillgänglig från: 2009-01-09 Skapad: 2009-01-09 Senast uppdaterad: 2019-05-15Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Ardlin, Berit I.Lindholm-Sethson, Britta

Sök vidare i DiVA

Av författaren/redaktören
Ardlin, Berit I.Lindholm-Sethson, Britta
Av organisationen
Institutionen för odontologiKemiska institutionen
I samma tidskrift
Journal of Biomedical Materials Research. Part B - Applied biomaterials
Odontologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 349 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf