Explanatory models for a tactile resonance sensor system-elastic and density-related variations of prostate tissue in vitro
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik. Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Centrum för medicinsk teknik och fysik (CMTF).
Umeå universitet, Medicinska fakulteten, Institutionen för medicinsk biovetenskap, Patologi.
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Urologi och andrologi.
Visa övriga samt affilieringar
2008 (Engelska)Ingår i: Physiological Measurement, ISSN 0967-3334, E-ISSN 1361-6579, Vol. 29, nr 7, s. 729-745Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Tactile sensors based on piezoelectric resonance have been adopted for medical applications. The sensor consists of an oscillating piezoelectric sensor–circuit system, and a change in resonance frequency is observed when the sensor tip contacts a measured object such as tissue. The frequency change at a constant applied force or mass load is used as a stiffness-sensitive parameter in many applications. Differential relations between force and frequency have also been used for monitoring intraocular pressure and stiffness variations in prostate tissue in vitro. The aim of this study was to relate the frequency change (Δf), measured force (F) and the material properties, density and elasticity to an explanatory model for the resonance sensor measurement principle and thereby to give explanatory models for the stiffness parameters used previously. Simulations of theoretical equations were performed to investigate the relation between frequency change and contact impedance. Measurements with a resonance sensor system on prostate tissue in vitro were used for experimental validation of the theory. Tissue content was quantified with a microscopic-based morphometrical method. Simulation results showed that the frequency change was dependent upon density (ρ) and contact area (S) according to Δf ∝ ρS3/2. The experiments followed the simulated theory at small impression depths. The measured contact force followed a theoretical model with the dependence of the elastic modulus (E) and contact area, FES3/2. Measured density variations related to histological variations were statistically weak or non-significant. Elastic variations were statistically significant with contributions from stroma and cancer relative to normal glandular tissue. The theoretical models of frequency change and force were related through the contact area, and a material-dependent explanatory model was found as Δf ∝ ρE−1F. It explains the measurement principle and the previously established stiffness parameters from the material properties point of view.

Ort, förlag, år, upplaga, sidor
Bristol: IOP Publ. Ltd , 2008. Vol. 29, nr 7, s. 729-745
Nyckelord [en]
tactile resonance sensor, density, elastic, variations, prostate tissue, stiffness, parameters, explanatory, models
Nationell ämneskategori
Medicinsk laboratorie- och mätteknik
Identifikatorer
URN: urn:nbn:se:umu:diva-10349DOI: 10.1088/0967-3334/29/7/003PubMedID: 18560055OAI: oai:DiVA.org:umu-10349DiVA, id: diva2:150020
Anmärkning
Tidigare titel: Elastic and density-related variations of prostate tissue in vitro as measured by a tactile resonance sensorTillgänglig från: 2008-08-15 Skapad: 2008-08-15 Senast uppdaterad: 2018-06-09Bibliografiskt granskad
Ingår i avhandling
1. Tactile sensing of prostate cancer: a resonance sensor method evaluated using human prostate tissue in vitro
Öppna denna publikation i ny flik eller fönster >>Tactile sensing of prostate cancer: a resonance sensor method evaluated using human prostate tissue in vitro
2007 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Prostate cancer is the most frequent type of cancer in men in Europe and the USA. The methods presently used to detect and diagnose prostate cancer are inexact, and new techniques are needed. Prostate tumours can be regarded as harder than the surrounding normal healthy glandular tissue, and therefore it is of interest to be able to reliably measure prostate tissue stiffness. In this dissertation the approach was to evaluate tactile resonance sensor technology and its ability to measure mechanical properties and to detect cancer in human prostate tissue.

The tactile resonance sensor is based on a piezoelectric transducer element vibrating at its resonance frequency through a feedback circuit. A change in the resonance frequency is observed when the sensor contacts an object. This feature has been utilized to measure tissue stiffness variations due to various pathophysiological conditions.

An impression-controlled tactile resonance sensor system was first used to quantify stiffness and evaluate performance on silicone. Then the sensor system was used on fresh human prostate tissue in vitro to measure stiffness using a combination of frequency change and force measurements. Significant differences in measured stiffness between malignant and healthy normal tissue were found, but there were large variations within the groups.

Some of the variability was explained by prostate tissue histology using a tissue stiffness model. The tissue content was quantified at four depths in the tissue specimens with a microscope-image-based morphometrical method involving a circular grid. Numerical weights were assigned to the tissue data from the four depths, and the weighted tissue proportions were related to the measured stiffness through a linear model which was solved with a least-squares method. An increase in the proportion of prostate stones, stroma, or cancer in relation to healthy glandular tissue increased the measured stiffness. Stroma and cancer had the greatest effect and accounted for 90 % of the measured stiffness (45% and 45%, respectively).

The deeper the sensor was pressed, the greater, i.e., deeper, volume it sensed. A sensing depth was extrapolated from the numerical weights for the measurements performed at different impression depths. Horizontal surface tissue variations were studied by altering the circular grid size relative to the contact area between the sensor tip and the tissue. The results indicated that the sensing area was greater than the contact area. The sensor registered spatial tissue variations.

Tissue density-related variations, as measured by the frequency change, were weakly significant or non-significant. The measured force registered elastic-related tissue variations, to which stroma and cancer were the most important variables.

A theoretical material-dependent linear relation was found between frequency change and force from theoretical models of frequency change and force. Tactile resonance sensor measurements on prostate tissue verified this at small impression depths. From this model, a physical interpretation was given to the parameters used to describe stiffness.

These results indicate that tactile resonance sensor technology is promising for assessing soft tissue mechanical properties and especially for prostate tissue stiffness measurement with the goal of detecting prostate cancer. However, further studies and development of the sensor design must be performed to determine the full potential of the method and its diagnostic power. Preferably, measurements of tissue mechanical properties should be used in combination with other methods, such as optical methods, to increase the diagnostic power.

Ort, förlag, år, upplaga, sidor
Umeå: Tillämpad fysik och elektronik, 2007. s. 70
Serie
Resonance Sensor Lab, ISSN 1653-6789 ; 4
Nyckelord
tactile resonance sensor, prostate tissue, prostate cancer, stiffness, density, elastic, variations, tissue histology
Nationell ämneskategori
Medicinsk laboratorie- och mätteknik
Identifikatorer
urn:nbn:se:umu:diva-1445 (URN)978-91-7264-461-8 (ISBN)
Disputation
2007-12-14, N430, Naturvetarhuset, Umeå universitet, Umeå, 10:00 (Engelska)
Opponent
Handledare
Tillgänglig från: 2007-11-22 Skapad: 2007-11-22 Senast uppdaterad: 2018-06-09Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Jalkanen, VilleAndersson, Britt MBergh, AndersLjungberg, Börje

Sök vidare i DiVA

Av författaren/redaktören
Jalkanen, VilleAndersson, Britt MBergh, AndersLjungberg, Börje
Av organisationen
Institutionen för tillämpad fysik och elektronikCentrum för medicinsk teknik och fysik (CMTF)PatologiUrologi och andrologi
I samma tidskrift
Physiological Measurement
Medicinsk laboratorie- och mätteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 599 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf