Maintaining Image Quality While Reducing Acoustic Noise and Switched Gradient Field Exposure During Lumbar MRI
Umeå University, Faculty of Medicine, Department of Nursing. Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.ORCID iD: 0000-0002-7480-770X
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Nursing. Umeå University, Faculty of Medicine, Umeå Centre for Functional Brain Imaging (UFBI).
2021 (English)In: Journal of Magnetic Resonance Imaging, ISSN 1053-1807, E-ISSN 1522-2586, Vol. 54, no 1, p. 315-325Article in journal (Refereed) Published
Abstract [en]

Background: MR-generated acoustic noise can contribute to patient discomfort and potentially be harmful. One way to reduce this noise is by altering the gradient output and/or waveform using software optimization. Such modifications might influence image quality and switched gradient field exposure, and different techniques appear to affect sound pressure levels (SPLs) to various degrees.

Purpose: To evaluate SPLs, image quality, switched gradient field exposure, and participants' perceived noise levels during two different acoustic noise reduction (ANR) techniques, Quiet Suite (QS) and Whisper Mode (WM), and to compare them with conventional T2-weighted turbo spin echo (T2W TSE) of the lumbar spine.

Design: Prospective.

Subjects: Forty adults referred for lumbar MRI.

Field strength/sequence: Conventional T2W TSE, T2W TSE with QS, and T2W TSE with WM were acquired at 1.5 T.

Assessment: Peak SPL (A-weighted decibels, dBA), perceived noise levels (Borg CR10®-scale), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), three radiologists' qualitative assessments in image quality on an ordinal scale 1-4, switched gradient field exposure (% general public), and gradient currents were measured. Interobserver reliability was reported as percentage agreement.

Statistical tests: Repeated measures ANOVA, Friedman's ANOVA, and Wilcoxon's Signed-Rank Test for acoustic noise measurements and image quality assessments.

Results: Mean peak SPLs were 89.9 dBA, 74.3 dBA, and 78.8 dBA for conventional, QS, and WM, respectively (P < 0.05). Participants perceived QS as the quietest and conventional as the loudest sequence (P < 0.05). No qualitative differences in image quality were seen (P > 0.05), although QS showed significantly improved SNR and CNR (P < 0.05). Switched gradient field exposure was reduced by 66% and 48% for QS and WM, respectively.

Data conclusion: Without degrading image quality, both QS and WM are viable ANR techniques in lumbar T2W TSE. QS provided the lowest SPL, the lowest gradient field exposure and was perceived as the most silent among the three sequences.

Level of evidence: 1 TECHNICAL EFFICACY STAGE: 5.

Place, publisher, year, edition, pages
John Wiley & Sons, 2021. Vol. 54, no 1, p. 315-325
Keywords [en]
MRI safety, magnetic field, patient comfort, quiet suite, whisper mode
National Category
Nursing
Identifiers
URN: urn:nbn:se:umu:diva-179857DOI: 10.1002/jmri.27527ISI: 000616367300001PubMedID: 33565199Scopus ID: 2-s2.0-85100635401OAI: oai:DiVA.org:umu-179857DiVA, id: diva2:1527503
Available from: 2021-02-11 Created: 2021-02-11 Last updated: 2022-05-12Bibliographically approved

Open Access in DiVA

fulltext(630 kB)258 downloads
File information
File name FULLTEXT02.pdfFile size 630 kBChecksum SHA-512
2ec250dbd384726d881f5186285944caceea626add145b3e289d8181c5dd76d71c4b4379314a164da62bd11c0f46396394e24edb9b1336e406d3d541059c4c0c
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Authority records

Glans, AntonWilén, JonnaLindgren, Lenita

Search in DiVA

By author/editor
Glans, AntonWilén, JonnaLindgren, Lenita
By organisation
Department of NursingRadiation PhysicsUmeå Centre for Functional Brain Imaging (UFBI)
In the same journal
Journal of Magnetic Resonance Imaging
Nursing

Search outside of DiVA

GoogleGoogle Scholar
Total: 387 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 398 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf