In situ gamma-ray spectrometry for environmental monitoring: a semi empirical calibration method.
Umeå University, Faculty of Medicine, Radiation Sciences, Radiation Physics.
Show others and affiliations
2006 (English)In: Radiation Protection Dosimetry, ISSN 0144-8420, Vol. 121, no 3, p. 310-316Article in journal (Refereed) Published
Place, publisher, year, edition, pages
2006. Vol. 121, no 3, p. 310-316
Identifiers
URN: urn:nbn:se:umu:diva-16618DOI: doi:10.1093/rpd/ncl041PubMedID: 16632586Scopus ID: 2-s2.0-33846051814OAI: oai:DiVA.org:umu-16618DiVA, id: diva2:156291
Available from: 2007-02-23 Created: 2007-02-23 Last updated: 2023-03-24Bibliographically approved
In thesis
1. Improving accuracy of in situ gamma-ray spectrometry
Open this publication in new window or tab >>Improving accuracy of in situ gamma-ray spectrometry
2008 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Gamma-ray spectrometry measurements performed on site, or “in situ”, is a widely used and powerful method that can be employed both to identify and quantify ground deposited radionuclides. The purpose of this thesis is to improve the calibration of high purity germanium (HPGe) detectors for in situ measurements, and calculate the combined uncertainty and potential systematic effects.

An improved semi-empirical calibration method is presented, based on a novel expression for the intrinsic detector efficiency that includes both the energy and angular response of the detector. A three-layer model for the description of the depth distribution of the radionuclide and the soil density is proposed. The combined uncertainty of intrinsic detector efficiency calibrations and in situ measurements according to the proposed method was estimated. The uncertainty in the intrinsic detector efficiency was found to be 5.1 and 8.1% (coverage factor k=1, i.e. for a confidence interval of about 68%), for the two detectors calibrated. These numbers were, however, at a later stage reduced to 3.7 and 4.2%, using a revised expression for the intrinsic detector efficiency.

For in situ measurements, the combined standard uncertainty was found to be 15-20% (k=1), based on the original expression for the intrinsic detector efficiency. Monte Carlo models of the two detectors were created and Monte Carlo calculated values for intrinsic detector efficiency were compared with experimental data. As a discrepancy was found, a thorough investigation of the detector response was performed. Scanning of the detector surface with a collimated 59.5 keV photon beam revealed the detector response to be highly irregular over the detector surface. It was concluded that the efficiency deficit of the detector could most likely be attributed to an increase in dead layer thickness compared with manufacturer supplied data. The thickness of the dead layer was estimated to be 1.5-1.9 mm, whereas the nominal value was 0.7 mm. Radiographs of the detectors were produced that provided valuable information about the physical dimensions of the germanium crystal, as well as its actual location within the detector housing.

The Monte Carlo models were employed to calculate in situ measurement efficiencies for measurements of 137Cs deposition from the Chernobyl fallout. Results from the Monte Carlo simulations were compared both with the semi-empirical method and with soil sample data, and satisfactory agreement was confirmed. It was then proceeded to employ the Monte Carlo model to calculate the effect on in situ measurement results by two influencing parameters: ground curvature and activity in trees. Neither of these parameters was found to influence the result by more than about 25%. This deviation is comparable with the measurement uncertainty, and should not deter from measurements in such terrain.

Place, publisher, year, edition, pages
Umeå: Radiofysik, 2008. p. 47
Series
Umeå University medical dissertations, ISSN 0346-6612 ; 1201
Keywords
gamma-ray spectrometry, in situ measurement, HPGe detector, 137Cs, Monte Carlo, efficiency calibration, measurement uncertainty
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
urn:nbn:se:umu:diva-1805 (URN)978-91-7264-621-6 (ISBN)
Public defence
2008-09-19, sal 244, by 7, NUS, Umeå, 09:00 (English)
Opponent
Available from: 2008-09-03 Created: 2008-09-03 Last updated: 2010-01-22Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Boson, Jonas

Search in DiVA

By author/editor
Boson, Jonas
By organisation
Radiation Physics

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 145 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf