Building energy parameter investigations based on multivariate analysis
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
2009 (Engelska)Ingår i: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 41, s. 71-80Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

System identification can be used for evaluations of how measured energy use is influenced by theoperation, design and equipment of buildings and their users. However, it can be difficult to accessappropriate data for modelling purposes due to a small number of buildings, parameters not distributednormally, lumped information, etc. In this work, data of a subset of 112 comparable multifamily buildingslocated in the Stockholm area were derived from a larger Swedish building energy consumption survey.In that database, the accessible data are monthly consumption data together with a large number ofbuilding-specific classification parameters, e.g. building code, age of control system, type of owner,maintenance organization, area to let, etc.A multivariate PLS method (partial least squares to latent structures) was used to model differentenergy performance measures, such as the use of energy for heating, electricity used to operate thebuilding technical system, the building total heat loss coefficient and the use of domestic cold water. ThePLS model was investigated for both the total annual use and the annual use normalized to the availablefloor area. For most measures of performance, only qualitative estimates of the impact of differentclassification parameters could be drawn due to the goodness value of the model. However, for some ofthe investigated parameters, quantitative estimates could also be drawn. The obtained results are, inmost cases, in good agreement with what might be expected.To enable benchmarking of different energy use measures, the area to let is commonly used as anormalizer by real estatemanagers in Sweden. In this study, we find strong indications that the area to letis not suitable for this purpose.

Ort, förlag, år, upplaga, sidor
Elsevier , 2009. Vol. 41, s. 71-80
Nyckelord [en]
Energy parameters, System identification, Residential buildings, Multivariate analysis, PLS
Identifikatorer
URN: urn:nbn:se:umu:diva-20064DOI: doi:10.1016/j.enbuild.2008.07.012OAI: oai:DiVA.org:umu-20064DiVA, id: diva2:208042
Tillgänglig från: 2009-03-26 Skapad: 2009-03-15 Senast uppdaterad: 2018-06-09Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Olofsson, ThomasAndersson, Staffan

Sök vidare i DiVA

Av författaren/redaktören
Olofsson, ThomasAndersson, Staffan
Av organisationen
Institutionen för tillämpad fysik och elektronik
I samma tidskrift
Energy and Buildings

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 243 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf