Development of a miniaturized diffusive sampler for true breathing-zone sampling and thermal desorption gas chromatographic analysis
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen.
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Kemiska institutionen. (Fenix Environmental, SE- 907 19 Umeå, Sweden)
Fenix Environmental, SE- 907 19 Umeå, Sweden.
2009 (engelsk)Inngår i: Journal of Environmental Monitoring, ISSN 1464-0325, E-ISSN 1464-0333, Vol. 11, nr 7, s. 1340-1344Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Exposure measurements should be performed as close as possible to the nose and mouth for a more correct assessment of exposure. User-friendly sampling equipment, with a minimum of handling before, during and after measurement, should not affect ordinary work. In diffusive (passive) sampling, no extra equipment as sampling pumps is needed, making the measurements more acceptable to the user. The diffusive samplers are normally attached on a shoulder, on a breast-pocket or on the lapel. There are, however, difficulties if true breathing-zone sampling is to be performed, since available diffusive samplers normally cannot be arranged close to the nose/mouth. The purpose of this work was to study the performance of a miniaturized tube type diffusive sampler attached to a headset for true breathing-zone sampling. The basis for this miniaturization was the Perkin Elmer ATD tube. Both the size of the tube and the amount of adsorbent was decreased for the miniaturized sampler. A special tube holder to be used with a headset was designed for the mini tube. The mini tube is thermally desorbed inside a standard PE tube. The new sampler was evaluated for the determination of styrene, both in laboratory experiments and in field measurements. As reference method, diffusive sampling with standard Perkin Elmer tubes, thermal desorption and gas chromatographic (GC) analysis was used. The sampling rate was determined to 0.356 mL min-1 (CV 9.6%) and was not significantly affected by concentration, sampling time or relative humidity.

 

sted, utgiver, år, opplag, sider
Royal Society of Chemistry, 2009. Vol. 11, nr 7, s. 1340-1344
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-25210DOI: 10.1039/b901926jOAI: oai:DiVA.org:umu-25210DiVA, id: diva2:229159
Tilgjengelig fra: 2009-08-11 Laget: 2009-08-11 Sist oppdatert: 2018-06-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Lindahl, RogerLevin, Jan-Olof

Søk i DiVA

Av forfatter/redaktør
Lindahl, RogerLevin, Jan-Olof
Av organisasjonen
I samme tidsskrift
Journal of Environmental Monitoring

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 102 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf