Capsule complication during cataract surgery: Case-control study of preoperative and intraoperative risk factors: Swedish Capsule Rupture Study Group report 2.
S:t Erik Eye Hospital, Stockholm.
EyeNet Sweden, Blekinge Hospital, Karlskrona.
Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.
Sahlgrenska University Hospital, Mölndal, .
Visa övriga samt affilieringar
2009 (Engelska)Ingår i: Journal of cataract and refractive surgery, ISSN 0886-3350, E-ISSN 1873-4502, ISSN ISSN 0886-3350, Vol. 35, nr 10, s. 1688-1693Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Abstract

PURPOSE: To identify preoperative and intraoperative factors associated with a capsule complication; that is, a capsule tear or a zonular dehiscence during cataract surgery. SETTING: Ten ophthalmic surgery departments in Sweden. METHODS: A retrospective review of files of patients with a capsule complication and control patients with no complication operated on in 2003 was performed. RESULTS: The review comprised 324 patients with a capsule complication and 331 control patients. In the logistic regression analyses, preoperative conditions associated with a capsule complication were previous trauma, white and brunescent/hard cataract, and phacodonesis. The intraoperative factors of loose zonules, the use of trypan blue, and miosis were all statistically significantly overrepresented in the capsule complication group. The same was true for eyes operated on by surgeons with the least experience. CONCLUSIONS: By preoperatively identifying cataract cases with the identified risk factors and allocating them to surgeons with the longest experience, the number of capsule complications could be kept low. Operating early in the course of the disease to prevent the cataract from becoming a poor surgical risk and improving training of junior surgeons should further reduce the frequency of capsule complications.

Ort, förlag, år, upplaga, sidor
2009. Vol. 35, nr 10, s. 1688-1693
Nyckelord [en]
Cataract surgery, capsule complication
Nationell ämneskategori
Oftalmologi
Forskningsämne
oftalmiatrik
Identifikatorer
URN: urn:nbn:se:umu:diva-33282DOI: 10.1016/j.jcrs.2009.05.026PubMedID: 19781460OAI: oai:DiVA.org:umu-33282DiVA, id: diva2:311233
Tillgänglig från: 2010-04-20 Skapad: 2010-04-20 Senast uppdaterad: 2018-06-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedhttp://www.jcrsjournal.org/article/S0886-3350(09)00655-5/abstract

Personposter BETA

Behndig, Anders

Sök vidare i DiVA

Av författaren/redaktören
Behndig, Anders
Av organisationen
Oftalmiatrik
I samma tidskrift
Journal of cataract and refractive surgery
Oftalmologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 696 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf