Exposure assessment of electromagnetic fields near electrosurgical units.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
2010 (Engelska)Ingår i: Bioelectromagnetics, ISSN 0197-8462, E-ISSN 1521-186X, Vol. 31, nr 7, s. 513-518Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Electrosurgical units (ESU) are widely used in medical health services. By applying sinusoidal or pulsed voltage in the frequency range of 0.3-5 MHz to the electrode tip, the desired mixture of coagulation and cutting are achieved. Due to the high voltage and current in the cable, strong electromagnetic fields appear near the ESU. The surgeon and others inside the operating room such as nurses, anesthesiologists, etc., will be highly exposed to these fields. The stray fields surrounding the ESU have previously been measured, but now a deeper analysis has been made of the curve shape of the field and the implication of this when assessing exposure from a commonly used ESU in accordance with the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. The result showed that for some of the modes, especially those using high-pulsed voltage with only a few sinusoidal periods, the E-field close to the cable could reach linear spatially averaged values of 20 kV/m compared to the 2.1 kV/m stated in ICNIRP guidelines. Assessing the E- and B-field from ESU is not straightforward since in this frequency range, both induced current density and specific absorption rate are restricted by the ICNIRP guidelines. Nevertheless, work needs to be done to reduce the stray fields from ESU. Bioelectromagnetics (c) 2010 Wiley-Liss, Inc.

Ort, förlag, år, upplaga, sidor
Wiley , 2010. Vol. 31, nr 7, s. 513-518
Nyckelord [en]
Surgical diathermia, magnetic field, electric field, ICNIRP
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:umu:diva-35830DOI: 10.1002/bem.20588ISI: 000282263100003PubMedID: 20607736OAI: oai:DiVA.org:umu-35830DiVA, id: diva2:349548
Tillgänglig från: 2010-09-07 Skapad: 2010-09-07 Senast uppdaterad: 2018-06-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Wilén, Jonna

Sök vidare i DiVA

Av författaren/redaktören
Wilén, Jonna
Av organisationen
Radiofysik
I samma tidskrift
Bioelectromagnetics
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 145 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf