Detection of myocardial ischaemia using surface microdialysis on the beating heart
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Anestesiologi och intensivvård.
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Anestesiologi och intensivvård.
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Anestesiologi och intensivvård.ORCID-id: 0000-0002-5325-2688
Umeå universitet, Medicinska fakulteten, Institutionen för kirurgisk och perioperativ vetenskap, Anestesiologi och intensivvård.
Visa övriga samt affilieringar
2011 (Engelska)Ingår i: Clinical Physiology and Functional Imaging, ISSN 1475-0961, E-ISSN 1475-097X, Vol. 31, nr 3, s. 175-181Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Microdialysis (MD) can be used to study metabolism of the beating heart. We investigated whether microdialysis results obtained from epicardial (surface) sampling reflect acute changes in the same way as myocardial sampling from within the substance of the ventricular wall. In anaesthetized open-thorax pigs a coronary snare was placed. One microdialysis probe was placed with the sampling membrane intramyocardially (myocardial), and a second probe was placed with the sampling membrane epicardially (surface), both in the area which was made ischaemic. Ten minutes collection intervals were used for microdialysis samples. Samples from 19 pigs were analysed for lactate, glucose, pyruvate and glycerol during equilibration, baseline, ischaemia and reperfusion periods. For both probes (surface and myocardial), a total of 475 paired simultaneous samples were analysed. Results from analyses showed no differences in relative changes for glucose, lactate and glycerol during baseline, ischaemia and reperfusion. Surface microdialysis sampling is a new application of the microdialysis technique that shows promise and should be further studied.

Ort, förlag, år, upplaga, sidor
2011. Vol. 31, nr 3, s. 175-181
Nyckelord [en]
epicardium; heart; ischaemia; metabolism; microdialysis; myocardium
Nationell ämneskategori
Fysiologi
Identifikatorer
URN: urn:nbn:se:umu:diva-39564DOI: 10.1111/j.1475-097X.2010.00995.xPubMedID: 21091606OAI: oai:DiVA.org:umu-39564DiVA, id: diva2:393896
Tillgänglig från: 2011-02-01 Skapad: 2011-02-01 Senast uppdaterad: 2018-06-08Bibliografiskt granskad
Ingår i avhandling
1. Methodological aspects on microdialysis sampling and measurements
Öppna denna publikation i ny flik eller fönster >>Methodological aspects on microdialysis sampling and measurements
2010 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Background:     The microdialysis (MD) technique is widely spread and used both experi­mentally and in clinical practice. The MD technique allows continuous collection of small molecules such as glucose, lactate, pyruvate and glycerol. Samples are often analysed using the CMA 600 analyser, an enzymatic and colorimetric analyser.  Data evaluating the performance of the CMA 600 analysis system and associated sample han­dling are sparse. The aim of this work was to identify sources of variability related to han­dling of microdialysis samples and sources of error associated with use of the CMA 600 analyser. Further, to develop and compare different application techniques of the micro­dialysis probes both within an organ and on the surface of an organ.

 Material and Methods:  Papers I and II are mainly in vitro studies with the exception of the No Net Flux calibration method in paper I where a pig model (n=7) was used to exam­ine the true concen­tration of glucose and urea in subcutaneous tissue. Flow rate, sampling time, vial and caps material and performance of the analyser device (CMA 600) were examined. In papers III and IV normoventilated anaesthetised pigs (n=33) were used. In paper III, heart ischemia was used as intervention to compare microdialysis measurements in the myocardium with corresponding measurements on the heart surface. In paper IV, microdialysis measurements in the liver parenchyma were compared with measurements on the liver surface in associa­tion with induced liver ischemia. All animal studies were approved by the Animal Experi­mental Ethics Committee at Umeå University Sweden.

Results:  In paper I we succeeded to measure true concentrations of glucose (4.4 mmol/L) and Urea (4.1 mmol/L) in subcutaneous tissue. Paper II showed that for a batch analyse of 24 samples it is preferred to store microdialysis samples in glass vials with crimp caps. For reliable results, samples should be centrifuged before analysis. Paper III showed a new application area for microdialysis sampling from the heart, i.e. surface sampling. The sur­face probe and myocardial probe (in the myocardium) showed a similar pattern for glucose, lactate and glycerol during baseline, short ischemic and long ischemic interventions. In paper IV, a similar pattern was observed as in paper III, i.e. data obtained from the probe on the liver surface showed no differences compared with data from the probe in liver paren­chyma for glucose, lactate and glycerol concentrations during baseline, ischemic and reperfusion interven­tions.

Conclusion:  The MD technique is adequate for local metabolic monitoring, but requires methodological considerations before starting a new experimental serie. It is important to consider factors such as flow rate, sampling time and handling of samples in association with the analysis device chosen. The main finding in this thesis is that analyses of glucose, lactate and glycerol in samples from the heart surface and liver surface reflect concentra­tions sampled from the myocardium and liver parenchyma, respectively.

Ort, förlag, år, upplaga, sidor
Umeå: Umeå universitet, 2010. s. 59
Serie
Umeå University medical dissertations, ISSN 0346-6612 ; 1380
Nyckelord
Microdialysis, liver ischemia, heart ischemia, epicardium, liver parenchyma, CMA 600, metabolism
Nationell ämneskategori
Anestesi och intensivvård
Forskningsämne
anestesiologi
Identifikatorer
urn:nbn:se:umu:diva-37464 (URN)978-91-7459-097-5 (ISBN)
Disputation
2010-11-26, Norrlands universitetssjukhus, Betula, 6M, Norrlands universitetssjukhus, 90185 Umeå, 09:00 (Svenska)
Opponent
Handledare
Tillgänglig från: 2010-11-11 Skapad: 2010-11-04 Senast uppdaterad: 2018-06-08Bibliografiskt granskad

Open Access i DiVA

fulltext(414 kB)328 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 414 kBChecksumma SHA-512
eced3e1f6529629900e0578bc4a54599e0a869ce3b6abbc6b49a1c35c6a26cdf410cc464431d22f53c379443fa0cfe3ef1125392d233e617e512b3782cc13799
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Abrahamsson, PernillaÅberg, Anna-MajaJohansson, GöranWinsö, OlaWaldenström, AndersHaney, Michael

Sök vidare i DiVA

Av författaren/redaktören
Abrahamsson, PernillaÅberg, Anna-MajaJohansson, GöranWinsö, OlaWaldenström, AndersHaney, Michael
Av organisationen
Anestesiologi och intensivvårdKardiologi
I samma tidskrift
Clinical Physiology and Functional Imaging
Fysiologi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 328 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 1602 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf