The inter-observer reliability is very low at clinical examination of parastomal hernia
Department of Surgical Gastroenterology, CLINTEC, Karolinska Institutet, Stockholm, Sweden; Department of Surgery, Nyköping Hospital, Nyköping, Sweden and Department of Surgical Gastroenterology, K53, Karolinska University Hospital, Huddinge, 141 86, Stockholm, Sweden .
Department of Surgery, Örebro University Hospital, Örebro, Sweden.
Department of Radiology, Akademiska University Hospital, Uppsala, Sweden.
Department of Surgery, Akademiska University Hospital, Uppsala, Sweden.
Visa övriga samt affilieringar
2011 (Engelska)Ingår i: International Journal of Colorectal Disease, ISSN 0179-1958, E-ISSN 1432-1262, Vol. 26, nr 1, s. 89-95Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

INTRODUCTION: Parastomal hernia in patients with a permanent colostomy is common. The aim of this study was to evaluate the reliability of the diagnosis based on clinical examination and to compare this examination with the result of a specially designed questionnaire and computerised tomography (CT) scan.

METHODS: Forty-one patients operated upon with an abdominoperineal resection due to rectal cancer at three hospitals between 1996 and 2002 were included. At minimum of 4 years after the operation, they underwent clinical examination by two or three independent surgeons, answered a colostomy questionnaire and were offered a CT scan of the abdominal wall.

RESULT: At Hospital I, 17 patients were examined by three surgeons, with inter-observer kappa values between 0.35 and 0.64. At Hospital II, 13 patients were examined by three surgeons, the kappa values ranged between 0.29 and 0.43. At Hospital III, 11 patients were examined by two surgeons, with kappa value of 0.73. The kappa value between CT scan and the colostomy questionnaire was 0.45.

CONCLUSION: The inter-observer reliability was low, indicating that parastomal hernia is difficult to diagnose by patient history and clinical examination. Some herniae may not be detected by CT scan, and the correlation to patient-reported complaints is low. A more sensitive radiological method to detect parastomal hernia is needed.

Ort, förlag, år, upplaga, sidor
Heidelberg: Springer Berlin/Heidelberg, 2011. Vol. 26, nr 1, s. 89-95
Nyckelord [en]
Parastomal, Hernia, Inter-observer, Reliability, CT scan
Nationell ämneskategori
Kirurgi
Identifikatorer
URN: urn:nbn:se:umu:diva-57216DOI: 10.1007/s00384-010-1050-2ISI: 000285785600011PubMedID: 20821218OAI: oai:DiVA.org:umu-57216DiVA, id: diva2:540516
Tillgänglig från: 2012-07-10 Skapad: 2012-07-10 Senast uppdaterad: 2018-06-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Rutegård, JörgenGunnarsson, Ulf

Sök vidare i DiVA

Av författaren/redaktören
Rutegård, JörgenGunnarsson, Ulf
Av organisationen
Kirurgi
I samma tidskrift
International Journal of Colorectal Disease
Kirurgi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 146 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf