umu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Blood flow of ophthalmic artery in healthy individuals determined by phase-contrast magnetic resonance imaging
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.ORCID-id: 0000-0003-2055-576X
Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.
Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Oftalmiatrik.
Visa övriga samt affilieringar
2013 (Engelska)Ingår i: Investigative Ophthalmology and Visual Science, ISSN 0146-0404, E-ISSN 1552-5783, Vol. 54, nr 4, s. 2738-2745Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

PURPOSE: Recent development of magnetic resonance imaging (MRI) offers new possibilities to assess ocular blood flow. This prospective study evaluates the feasibility of phase-contrast MRI (PCMRI) to measure flow rate in the ophthalmic artery (OA) and establish reference values in healthy young (HY) and elderly (HE) subjects.

METHODS: Fifty HY subjects (28 females, 21-30 years of age) and 44 HE (23 females, 64-80 years of age) were scanned on a 3-Tesla MR system. The PCMRI sequence had a spatial resolution of 0.35 mm per pixel, with the measurement plan placed perpendicularly to the OA. Mean flow rate (Qmean), resistive index (RI), and arterial volume pulsatility of OA (ΔVmax) were measured from the flow rate curve. Accuracy of PCMRI measures was investigated using a vessel-phantom mimicking the diameter and the flow rate range of the human OA.

RESULTS: Flow rate could be assessed in 97% of the OAs. Phantom investigations showed good agreement between the reference and PCMRI measurements with an error of <7%. No statistical difference was found in Qmean between HY and HE individuals (HY: mean ± SD = 10.37 ± 4.45 mL/min; HE: 10.81 ± 5.15 mL/min, P = 0.655). The mean of ΔVmax (HY: 18.70 ± 7.24 μL; HE: 26.27 ± 12.59 μL, P < 0.001) and RI (HY: 0.62 ± 0.08; HE: 0.67 ± 0.1, P = 0.012) were significantly different between HY and HE.

CONCLUSIONS: This study demonstrated that the flow rate of OA can be quantified using PCMRI. There was an age difference in the pulsatility parameters; however, the mean flow rate appeared independent of age. The primary difference in flow curves between HE and HY was in the relaxation phase of the systolic peak.

Ort, förlag, år, upplaga, sidor
2013. Vol. 54, nr 4, s. 2738-2745
Nyckelord [en]
magnetic resonance imaging, blood flow, ophthalmic artery
Nationell ämneskategori
Oftalmologi
Identifikatorer
URN: urn:nbn:se:umu:diva-73723DOI: 10.1167/iovs.13-11737ISI: 000319821700039PubMedID: 23518769OAI: oai:DiVA.org:umu-73723DiVA, id: diva2:633456
Tillgänglig från: 2013-06-27 Skapad: 2013-06-27 Senast uppdaterad: 2018-06-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Ambarki, KhalidHallberg, PerJóhannesson, GautiLindén, ChristinaZarrinkoob, LalehWåhlin, AndersBirgander, RichardMalm, JanEklund, Anders

Sök vidare i DiVA

Av författaren/redaktören
Ambarki, KhalidHallberg, PerJóhannesson, GautiLindén, ChristinaZarrinkoob, LalehWåhlin, AndersBirgander, RichardMalm, JanEklund, Anders
Av organisationen
RadiofysikOftalmiatrikKlinisk neurovetenskapUmeå centrum för funktionell hjärnavbildning (UFBI)Diagnostisk radiologi
I samma tidskrift
Investigative Ophthalmology and Visual Science
Oftalmologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 1433 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf