Evaluation of Achilles and patellar tendinopathy with greyscale ultrasound and colour Doppler: using a four-grade scale
Umeå universitet, Medicinska fakulteten, Institutionen för klinisk vetenskap, Professionell utveckling.
Visa övriga samt affilieringar
2016 (Engelska)Ingår i: Knee Surgery, Sports Traumatology, Arthroscopy, ISSN 0942-2056, E-ISSN 1433-7347, Vol. 24, nr 6, s. 1988-1996Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

PURPOSE: In tendon research, using ultrasound (US), studies often refer to tendon thickness, structural abnormalities and neovascularisation. The reliability concerning these measurements and evaluations is seldom reported. The aim of this study was to assess the intra- and inter-observer reliability for quantitative measures (thickness) and qualitative evaluations (structure and neovascularisation) of symptomatic and asymptomatic Achilles and patellar tendons with US and colour Doppler using a modified Öhberg score.

METHODS: Twenty-eight consecutive patients with symptomatic and asymptomatic Achilles (n = 27) and patellar tendons (n = 26) were included. Tendon anteroposterior thickness was measured. Tendon structure and neovascularisation were evaluated using a modified Öhberg score. US-images were evaluated twice by four independent observers.

RESULTS: Mean thickness for Achilles and patellar tendons was 8.4 mm (±2.0) and 5.5 mm (±1.7), respectively. The reliability for measures of distance was high all over (ICC = 0.963-0.999). A moderate-strong correlation was found between observers concerning evaluation of neovascularisation (r = 0.767-0.992) and poor-moderate correlation concerning evaluation of structural changes (r = 0.379-0.837). Intra-observer reliability was moderate strong for evaluations of both tendon structure (k = 0.537-0.873) and neovascularisation (k = 0.639-0.864).

CONCLUSIONS: With a strict method for how to measure tendon thickness and set criteria for evaluating structural changes and amount and distribution of neovascularisation, US and colour Doppler is a reliable method for evaluating Achilles and patellar tendons. The modified, 4-graded, Öhberg score was found to be a reproducible instrument for assessment of tendon structure and neovascularisation.

Ort, förlag, år, upplaga, sidor
2016. Vol. 24, nr 6, s. 1988-1996
Nyckelord [en]
Echogenicity, Inter-observer reliability, Neovascularisation, Tendon structure, Öhberg score
Nationell ämneskategori
Idrottsvetenskap
Identifikatorer
URN: urn:nbn:se:umu:diva-101455DOI: 10.1007/s00167-014-3270-4ISI: 000377019200032PubMedID: 25193569OAI: oai:DiVA.org:umu-101455DiVA, id: diva2:799317
Tillgänglig från: 2015-03-30 Skapad: 2015-03-30 Senast uppdaterad: 2018-06-07Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Fahlström, Martin

Sök vidare i DiVA

Av författaren/redaktören
Fahlström, Martin
Av organisationen
Professionell utveckling
I samma tidskrift
Knee Surgery, Sports Traumatology, Arthroscopy
Idrottsvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 492 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf