Characterization of HPGe detectors using Computed Tomography
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik. Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå, Sweden.
Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå, Sweden.
Swedish Defence Research Agency, Division of CBRN Defence and Security, SE-90182 Umeå, Sweden.
Umeå universitet, Medicinska fakulteten, Institutionen för strålningsvetenskaper, Radiofysik.
Visa övriga samt affilieringar
2015 (Engelska)Ingår i: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, Vol. 785, nr 11 June 2015, s. 21-25Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Computed Tomography (CT) high resolution imaging have been used to investigate if there is a significant change in the crystal-to-window distance, i.e. the air gap thickness, in a small n-type detector cooled to 77 K, and in a medium sized p-type HPGe detector when cooled to 100 K. The findings were compared to detector dimension data made available by the manufacturer. The air gap thickness increased by (0.38 +/- 0.07) mm for the n-type detector and by (0.40 +/- 0.15) mm for the p-type detector when the detectors were cooled to 77 resp. 100 K compared to at room temperature. Monte Carlo calculations indicate that these differences have a significant impact on the efficiency in close geometries (< 5 cm). In the energy range of 40-700 keV with a source placed directly on endcap, the change in detector efficiency with temperature is 1.9-2.9% for the n-type detector and 0.3-2.1% for the p-type detector. The measured air gap thickness when cooling the detector was 1.1 mm thicker than manufacturer data for the n-type detector and 0.2 mm thicker for the p-type detector. In the energy range of 40-700 keV and with a source on endcap, this result in a change in detector efficiency of 5.2-7.1% for the n-type detector and 0.2-1.0% for the p-type detector, Le the detector efficiency is overestimated using data available by the manufacturer. (C) 2015 Elsevier B.V. All rights reserved.

Ort, förlag, år, upplaga, sidor
Elsevier, 2015. Vol. 785, nr 11 June 2015, s. 21-25
Nyckelord [en]
Gamma spectrometry, HPGe, Computed Tomography, Monte Carlo modelling, Gespecor, Semi-empirical calibration
Nationell ämneskategori
Medicinsk bildbehandling
Identifikatorer
URN: urn:nbn:se:umu:diva-103122DOI: 10.1016/j.nima.2015.02.041ISI: 000352815400005OAI: oai:DiVA.org:umu-103122DiVA, id: diva2:814117
Tillgänglig från: 2015-05-26 Skapad: 2015-05-18 Senast uppdaterad: 2018-06-07Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Hedman, AngelicaJohansson, LennartAndersson, Jonas S.

Sök vidare i DiVA

Av författaren/redaktören
Hedman, AngelicaJohansson, LennartAndersson, Jonas S.
Av organisationen
RadiofysikInstitutionen för strålningsvetenskaper
I samma tidskrift
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Medicinsk bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 315 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf