umu.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Sulfatmätningar i kokeriet
Umeå universitet, Teknisk-naturvetenskapliga fakulteten, Institutionen för tillämpad fysik och elektronik.
2015 (svensk)Independent thesis Basic level (university diploma), 5 poäng / 7,5 hpOppgave
Abstract [sv]

Arbetet har mestadels utförts i kokeriet på Domsjö Fabriker i syfte att kartlägga hur processförhållandena hänger samman med koncentrationen sulfatjoner. Detta för att lättare kunna undvika förhållanden i processen som innebär mycket höga värden. Arbetet ingår i examen för högskoleutbildningen: processoperatör vid Umeå Universitet.Vid Domsjö Fabriker har tidigare liknande mätningar gjorts i kokeriet och det har konstaterats att koncentrationen sulfatjoner hänger samman med pH och tid. Syftet är att djupare kartlägga hur processförhållandena hänger samman för att lättare kunna undvika förhållanden som innebär höga koncentrationer sulfatjoner. Målet med examensarbetet och dess undersökning är att sammanställa resultat som visar hur och när under koket som sulfatjoner bildas i stora mängder i kokeriet. Förfarandet av undersökningen har bestått i att prov tas ut i provserier om fyra provtillfällen per kok, fryses in och slutligen analyseras genom titrering och pH-mätning.Efter totalt 22 stycken provserier om fyra prov från de olika kokarna konstaterades att sulfatkoncentrationen är högst i slutet av nedgasningssteget. Det första provtillfället hade de högsta pH-värdena men också de lägsta koncentrationerna sulfat. Inget av dessa värden sticker ur och anses onormalt på något sätt. Om sulfatkoncentrationen påverkas av pH-värdet går inte att fastställa av detta arbete, då det inte är de lägsta pH-värdena som genererar de högsta sulfatkoncentrationerna utifrån resultatet i undersökningen.

Abstract [en]

This work has been performed in the digester at Domsjö Fabriker in order to clarify the concentration of sulphate-ions comparing to different driving-conditions in the process. The reason to this is to understand and be able to avoid conditions in the digester process that means very high concentrations of sulphate-ions. The work is included in the examination of higher education: process operator at Umeå University.At Domsjö Fabriker similar studies have been done in the digester and from that it has been found out that the concentration of sulphate-ions is connected to pH and over time. The purpose is to approve the understanding of the process conditions to avoid extremely high concentration of sulphate-ions. The mission with this work and the measurements included in the work is to put together results that show when the concentration of sulphate-ions is high. The procedure of the study has consisted in taking samples in series of four, frozen the samples and finally analyzing them by titration and pH-measurements.After 22 evaluated trial-series á four samples each from the boilers it was concluded that the concentration of sulphate-ions was the greatest in the end of this process-step. The pH was upper and the concentration of sulphate lower in the first sample. None of the data is abnormal in any way, and they are all connected and relevant to each other. In this experiment it is not possible to state if the concentration of sulphate is affected by the pH or not.

sted, utgiver, år, opplag, sider
2015. , s. 26
Emneord [en]
Sulphate-ions (SO42-), digester, titration
Emneord [sv]
sulfatjoner (SO42-), kokeri, titrering
HSV kategori
Identifikatorer
URN: urn:nbn:se:umu:diva-104912OAI: oai:DiVA.org:umu-104912DiVA, id: diva2:821725
Eksternt samarbeid
Domsjö Fabriker
Utdanningsprogram
University Diploma Programme for Process Operators
Veileder
Examiner
Tilgjengelig fra: 2015-08-31 Laget: 2015-06-15 Sist oppdatert: 2015-08-31bibliografisk kontrollert

Open Access i DiVA

fulltext(1158 kB)294 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1158 kBChecksum SHA-512
5900c36aa3e100522b90511048d7fc56c32c21004b103ac5cc8c4df382e6f68a586553bb665190dd12f40dfdbf57962deec6269189d1bc3b2f4b3f702f0ecbbd
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 294 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 229 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf