Dynamic model for measurement of convective heat transfer coefficient at external building surfaces
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2016 (English)In: Journal of Building Engineering, ISSN 2352-7102, Vol. 7, p. 239-245Article in journal (Refereed) Published
Abstract [en]

Uncertainties in current empirical models for the convective heat transfer coefficient (CHTC) have large impact on the accuracy of building energy simulations (BES). These models are often based on measurements of the CHTC, using a heated gradient sensor, where steady-state convective air flow is assumed. If this requirement is not fulfilled there will be a dynamic measurement error. The objectives were to construct a validated dynamic model for the heated gradient sensor, and to use this model to improve accuracy by suggesting changes in sensor design and operating procedure. The linear thermal network model included three state-space variables, selected as the temperatures of the three layers of the heated gradient sensor. Predictions of the major time constant and temperature time evolution were in acceptable agreement with experimental results obtained from step-response experiments. Model simulations and experiments showed that the sensor time constant increases with decreasing CHTC value, which means that the sensor response time is at maximum under free convection conditions. Under free convection, the surface heat transfer resistance is at maximum, which cause enhanced heat loss through the sensor insulation layer. Guidelines are given for selection of sampling frequency, and for evaluation of dynamic measurement errors.

Place, publisher, year, edition, pages
Elsevier, 2016. Vol. 7, p. 239-245
Keywords [en]
Convective heat transfer coefficient, Heat balance, Measurement uncertainty, Thermal network modelling, Dynamic sensor model
National Category
Other Physics Topics
Identifiers
URN: urn:nbn:se:umu:diva-121735DOI: 10.1016/j.jobe.2016.06.005ISI: 000397386000024Scopus ID: 2-s2.0-84978427729OAI: oai:DiVA.org:umu-121735DiVA, id: diva2:934049
Funder
The Kempe FoundationsSwedish Energy Agency, 39699-1Available from: 2016-06-08 Created: 2016-06-08 Last updated: 2018-08-08Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records BETA

Ohlsson, K.E. AndersÖstin, RonnyStaffan, GrundbergOlofsson, Thomas

Search in DiVA

By author/editor
Ohlsson, K.E. AndersÖstin, RonnyStaffan, GrundbergOlofsson, Thomas
By organisation
Department of Applied Physics and Electronics
Other Physics Topics

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 1503 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf