CCD-baserad avvikelsemätning på röntgenstrålfältskant: Framtagande av en prototyp för mätning av avvikelse mellan röntgenstrålfält och ljusfält vid konventionell röntgen
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2016 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
CCD based x-ray field congruence measurement : Development of a prototype for field congruence measurement between x-ray and light field at conventional radiography equipment (English)
Abstract [sv]

Denna rapport presenterar utvecklingen av ett mätverktyg för kontrollmätning av överensstämmelse mellan ljusfält och röntgenstrålfält på ett konventionellt röntgensystem.

 

Projektet resulterade i en prototyp som använder CCD- linjesensorer för att mäta ljusintensitet och identifiera fältkanter. I en sensoruppsättning är den ena av två sensorer exponerad genom ett hål i höljet medan den andra är inkapslad och täckt med en tunn skärm av fluorescerande material. Prototypen är en fristående batteridriven enhet med ett eget interface där en TFT skärm och knappar används för navigering i menyer. Prototypen beräknar avvikelsen med en säkerhet på <1mm (teoretiskt lägre). Alla komponenter är monterade i ett 3D-printat hölje.

 

Arbetet utfördes som ett projekt på uppdrag av Landstinget i Värmland som tillhandahållit med stöd och röntgenutrustning för testmätningar. Projektet omfattar kretskortskonstruktion, 3D-design i CAD, elektronikkonstruktion och mjukvarudesign i programmeringsspråket C.

Abstract [en]

This report presents the development of a measurement device for field congruence measurement between light and x-ray field at conventional radiography equipment.

The project resulted in a prototype which uses CCD-line sensors to measure light intensity and determine field edges. In a sensor set one sensor is exposed through a hole in the protective casing while the second sensor is incased and covered with a thin screen of fluorescent material. The prototype is a stand-alone, battery powered unit with an interface were a TFT-screen and buttons is used to navigate in menus.

The prototype calculate the congruence within <1mm certainty (theoretically lower). All components are mounted in a 3D printed casing.

 

This work has been executed as a project on behalf of the County Council of Värmland, who provided with support and x-ray equipment for test measurements. The project includes PCB-construction, 3D-design in CAD, electronics construction and software development in the programing language C.    

Place, publisher, year, edition, pages
2016. , 24 p.
National Category
Medical Equipment Engineering
Identifiers
URN: urn:nbn:se:umu:diva-126393OAI: oai:DiVA.org:umu-126393DiVA: diva2:1015032
External cooperation
Landstinget i Värmland
Subject / course
Elektronik
Educational program
Bachelor of Science Programme in Electronic and Computer Engeneering/ Medical engineering
Supervisors
Examiners
Available from: 2016-10-04 Created: 2016-10-03 Last updated: 2016-10-04Bibliographically approved

Open Access in DiVA

fulltext(1788 kB)37 downloads
File information
File name FULLTEXT01.pdfFile size 1788 kBChecksum SHA-512
27245ae5c1519c8cf7aa591a107cb5dae64de281b2343bed9c3bc9810ac7daaae340b28c138b5e7f3bed24ba589d6108ae5d6eb0d83c406dfa6e7d7c8511a5c8
Type fulltextMimetype application/pdf

By organisation
Department of Applied Physics and Electronics
Medical Equipment Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 37 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 44 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf