Surgical Replacement of Implantable Pulse Generator in Deep Brain Stimulation: Adverse Events and Risk Factors in a Multicenter Cohort
Umeå University, Faculty of Medicine, Department of Pharmacology and Clinical Neuroscience, Clinical Neuroscience. Neurosurgery, Department of Clinical Neuroscience, Karolinska Institutet, Stockholm. Asia-Pacific Centre for Neuromodulation, Queensland Brain Institute, University of Queensland.
Umeå University, Faculty of Medicine, Department of Pharmacology and Clinical Neuroscience, Clinical Neuroscience. Department of Neurosurgery, Sahlgrenska University Hospital, Göteborg.
Show others and affiliations
2016 (English)In: Stereotactic and Functional Neurosurgery, ISSN 1011-6125, E-ISSN 1423-0372, Vol. 94, no 4, p. 235-239Article in journal (Refereed) Published
Abstract [en]

Background: Deep brain stimulation (DBS) is a growing treatment modality, and most DBS systems require replacement of the implantable pulse generator (IPG) every few years. The literature regarding the potential impact of adverse events of IPG replacement on the longevity of DBS treatments is rather scarce. Objective: To investigate the incidence of adverse events, including postoperative infections, associated with IPG replacements in a multicenter cohort. Methods: The medical records of 808 patients from one Australian and five Swedish DBS centers with a total of 1,293 IPG replacements were audited. A logistic regression model was used to ascertain the influence of possible predictors on the incidence of adverse events. Results: The overall incidence of major infections was 2.3% per procedure, 3.7% per patient and 1.7% per replaced IPG. For 28 of 30 patients this resulted in partial or complete DBS system removal. There was an increased risk of infection for males (OR 3.6, p = 0.026), and the risk of infection increased with the number of prior IPG replacements (OR 1.6, p < 0.005). Conclusions: The risk of postoperative infection with DBS IPG replacement increases with the number of previous procedures. There is a need to reduce the frequency of IPG replacements. 

Place, publisher, year, edition, pages
2016. Vol. 94, no 4, p. 235-239
National Category
Surgery
Identifiers
URN: urn:nbn:se:umu:diva-128489DOI: 10.1159/000447521ISI: 000387199800005PubMedID: 27554079Scopus ID: 2-s2.0-84983738531OAI: oai:DiVA.org:umu-128489DiVA, id: diva2:1052026
Available from: 2016-12-05 Created: 2016-12-05 Last updated: 2023-03-24Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Fytagoridis, AndersSamuelsson, JenniferBlomstedt, Patric

Search in DiVA

By author/editor
Fytagoridis, AndersSamuelsson, JenniferBlomstedt, Patric
By organisation
Clinical Neuroscience
In the same journal
Stereotactic and Functional Neurosurgery
Surgery

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 478 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf