umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Power-performance tradeoffs in data center servers: DVFS, CPUpinning, horizontal, and vertical scaling
Umeå University, Faculty of Science and Technology, Department of Computing Science. (Distributed Systems)ORCID iD: 0000-0001-8178-3921
Umeå University, Faculty of Science and Technology, Department of Computing Science. (Distributed Systems)
Department of Information Technology, Uppsala University, SE-751 05 Uppsala, Sweden.
Umeå University, Faculty of Science and Technology, Department of Computing Science. (Distributed Systems)
Show others and affiliations
2018 (English)In: Future generations computer systems, ISSN 0167-739X, E-ISSN 1872-7115, Vol. 81, 114-128 p.Article in journal (Refereed) Published
Abstract [en]

Dynamic Voltage and Frequency Scaling (DVFS), CPU pinning, horizontal, and vertical scaling, are four techniques that have been proposed as actuators to control the performance and energy consumption on data center servers. This work investigates the utility of these four actuators, and quantifies the power-performance tradeoffs associated with them. Using replicas of the German Wikipedia running on our local testbed, we perform a set of experiments to quantify the influence of DVFS, vertical and horizontal scaling, and CPU pinning on end-to-end response time (average and tail), throughput, and power consumption with different workloads. Results of the experiments show that DVFS rarely reduces the power consumption of underloaded servers by more than 5%, but it can be used to limit the maximal power consumption of a saturated server by up to 20% (at a cost of performance degradation). CPU pinning reduces the power consumption of underloaded server (by up to 7%) at the cost of performance degradation, which can be limited by choosing an appropriate CPU pinning scheme. Horizontal and vertical scaling improves both the average and tail response time, but the improvement is not proportional to the amount of resources added. The load balancing strategy has a big impact on the tail response time of horizontally scaled applications.

Place, publisher, year, edition, pages
2018. Vol. 81, 114-128 p.
Keyword [en]
Power-performance tradeoffs, Dynamic Voltage and Frequency Scaling (DVFS), CPU pinning, Horizontal scaling, Vertical scaling
National Category
Computer Systems
Research subject
Computer Science
Identifiers
URN: urn:nbn:se:umu:diva-132427DOI: 10.1016/j.future.2017.10.044Scopus ID: 2-s2.0-85033772481OAI: oai:DiVA.org:umu-132427DiVA: diva2:1081323
Note

Originally published in thesis in manuscript form.

Available from: 2017-03-13 Created: 2017-03-13 Last updated: 2018-01-04Bibliographically approved
In thesis
1. Analysing, modelling and controlling power-performance tradeoffs in data center infrastructures
Open this publication in new window or tab >>Analysing, modelling and controlling power-performance tradeoffs in data center infrastructures
2017 (English)Licentiate thesis, comprehensive summary (Other academic)
Alternative title[sv]
Analys, modellering och reglering för avvägning mellan prestanda och strömförbrukning i datacenter
Abstract [en]

The aim of this thesis is to analyse the power-performance tradeoffs in datacenter servers, create models that capture these tradeoffs, and propose controllers to optimise the use of data center infrastructures taking the tradeoffs into consideration. The main research problem that we investigate in this thesis is how to increase the power efficiency of data center servers taking into account the power-performance tradeoffs.

The main cause for this research is the massive power consumption of data centers that is a concern both from the financial and environmental footprint perspectives. Irrespectively of the approaches taken to enhance data center power efficiency, substantial reductions in the power consumption of data center servers easily lead to performance degradation of hosted applications, which causes customers dissatisfaction. Therefore, it is crucial for the data center operators to understand and control the power-performance tradeoffs.

The research methods used in this thesis include experiments on real testbeds, applying statistical methods to create power-performance models, development of various optimisation techniques to improve the energy-efficiency of servers, and simulations to evaluate proposed solutions at scale.

As a result of the research presented in this thesis, we propose taxonomies for selected aspects of data center configurations, events, management actions, and monitored metrics. We discuss the relationships between these elements and to support the analysis present results from a set of testbed experiments.We show limitations in the applicability of various data center management actions, including Dynamic Voltage Frequency Scaling (DVFS), Running Average Power Limit (RAPL), CPU Pinning, horizontal and vertical scaling. Finally, we propose a power budgeting controller that minimizes the performance degradation while enforcing the power limits.

The outcomes of this thesis can be used by the data center operators to improve the energy-efficiency of servers and reduce the overall power consumption with minimized performance degradation. Moreover, the software artifacts including virtual machine images, scripts, and simulator are available online.

Future work includes further investigation of the problem of graceful performance degradation under power limits, incorporating multi-layer applications spread among several servers and load balancing controller.

Place, publisher, year, edition, pages
Umeå: Umeå University, 2017
Series
Report / UMINF, ISSN 0348-0542 ; 17.04
National Category
Computer Systems
Identifiers
urn:nbn:se:umu:diva-132430 (URN)978-91-7601-683-1 (ISBN)
Presentation
2017-03-28, N360, Naturvetarhuset, Universitetsvägen, Umeå, 13:15 (English)
Supervisors
Available from: 2017-04-13 Created: 2017-03-13 Last updated: 2017-04-13Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Krzywda, JakubAli-Eldin, AhmedÖstberg, Per-OlovElmroth, Erik
By organisation
Department of Computing Science
In the same journal
Future generations computer systems
Computer Systems

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 97 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf