umu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Effect of gradient field nonlinearity distortions in MRI-based attenuation maps for PET reconstruction
Umeå University, Faculty of Medicine, Department of Radiation Sciences.
Umeå University, Faculty of Medicine, Department of Radiation Sciences. Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, United States.
Umeå University, Faculty of Medicine, Department of Radiation Sciences.
Umeå University, Faculty of Medicine, Department of Radiation Sciences.
Show others and affiliations
2017 (English)In: Physica medica (Testo stampato), ISSN 1120-1797, E-ISSN 1724-191X, Vol. 35, 1-6 p.Article in journal (Refereed) Published
Abstract [en]

Purpose: Attenuation correction is a requirement for quantification of the activity distribution in PET. The need to base attenuation correction on MRI instead of CT has arisen with the introduction of integrated PET/MRI systems. The aim was to describe the effect of residual gradient field nonlinearity distortions on PET attenuation correction.

Methods: MRI distortions caused by gradient field nonlinearity were simulated in CT images used for attenuation correction in PET reconstructions. The simulations yielded radial distortion of up to  at 15 cm from the scanner isocentre for distortion corrected images. The mean radial distortion of uncorrected images were 6.3 mm at the same distance. Reconstructions of PET data were performed using the distortion corrected images as well as the images where no correction had been applied.

Results: The mean relative difference in reconstructed PET uptake intensity due to incomplete distortion correction was less than ±5%. The magnitude of this difference varied between patients and the size of the distortions remaining after distortion correction.

Conclusions: Radial distortions of 2 mm at 15 cm radius from the scanner isocentre lead to PET attenuation correction errors smaller than 5%. Keeping the gradient field nonlinearity distortions below this limit can be a reasonable goal for MRI systems used for attenuation correction in PET for quantification purposes. A higher geometrical accuracy may, however, be warranted for quantification of peripheral lesions. These distortions can, e.g., be controlled at acceptance testing and subsequent quality assurance intervals.

Place, publisher, year, edition, pages
2017. Vol. 35, 1-6 p.
Keyword [en]
MRI, PET, Quality assurance, Attenuation correction, MRI distortions
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:umu:diva-133798DOI: 10.1016/j.ejmp.2017.02.019ISI: 000397945200001PubMedID: 28283354OAI: oai:DiVA.org:umu-133798DiVA: diva2:1089978
Available from: 2017-04-21 Created: 2017-04-21 Last updated: 2017-04-21Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Lundman, Josef A.Johansson, AdamOlofsson, JörgenAxelsson, JanLarsson, AnneNyholm, Tufve
By organisation
Department of Radiation Sciences
In the same journal
Physica medica (Testo stampato)
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 12 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf